DCE33
TO INSTALL: Plumbing
Free Standing
Cabinet,
Pump Model:
1. Remove
the kickptate
and control box cover.
2. Route the water supply, which should
be a 1/4"
O.D. copper tube through
the back of the cabinet
to the front.
3. Install a flare nut and flare the end of the tube.
4. Flush the water line and fasten the flare nut to
the male flare on the inlet water valve.
5. Locate the coil of 3/8" ID plastic drain tubing
secured
to the back of the cabinet.
6. Route the plastic drain tubing
to the drain point
connection.
Do not connect
to a drain/waste
line
below a trap. Connect
the discharge
line to the
drain, per local codes. An air gap will likely be
required
between
the ice machine
drain tube and
the drain/waste
receptacle.
7. Turn on the water and plug in the ice machine.
Pour a couple quarts of water in the bin, the drain
pump should
start. Check for water leaks.
8. Replace the kickptate
and control box cover.
9. Level the unit using the leg levelers.
ALL PLUMBING
MUST MEET LOCAL CODES
THE DCE33 WILL FIT IN A SPACE
151/4" WIDE X 333/4" HIGH.
THE DEPTH OF THE CABINET IS 22" TO
THE FRONT EDGE OF THE HANDLE.
Air Gap Device
(Where Required)
Drain
Connection
WATER AND DRAIN
INS TA LLA TION
Water Sh ut
Off Valve
Drain Tube
From Back Of
Machine
Water Filter
(Recommended)
June 2000
Page 6
Water Inlet Connection