Genie TriloG 1200 Operation And Maintenance Manual

Genie TriloG 1200 Operation And Maintenance Manual

Professional line
Hide thumbs Also See for TriloG 1200:

Advertisement

T rilo G
1200
Model 3064 & 3064H
GARAGE DOOR OPENER
OPERATION AND MAINTENANCE MANUAL
Includes INTELLICODE
2 Remote Control. Safe-T-Beam
System must be installed to close door.
®
®
Homelink
and Car2U
compatible.
®
®
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
WARNING: To reduce the risk of injury to persons or damage to property – Use this opener only with a one piece
or sectional door.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
INSTALLER:
LEAVE THIS MANUAL WITH HOMEOWNER.
Genie, Genie logo, Intellicode and Safe-T-Beam are registered trademarks and TriloG is a trademark of GMI holdings, Inc., dba The Genie Company.
Homelink
is a registered trademark of Johnson Controls Technology Company. Car2U
is a registered trademark of Lear Corporation. © 2010 The Genie Company PN# 37064500118, 12/2010
®
®
PN# 37026500017, 3/30/2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TriloG 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Genie TriloG 1200

  • Page 1 SAVE THIS MANUAL FOR FUTURE REFERENCE. INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. Genie, Genie logo, Intellicode and Safe-T-Beam are registered trademarks and TriloG is a trademark of GMI holdings, Inc., dba The Genie Company. Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation.
  • Page 2: Safety Information

    Could result in Death or Serious Installations, repairs and adjustments must be done by Injury a trained door system technician using proper tools and instructions. ©2010 The Genie Company 12/2010...
  • Page 3: Opener Features & Safety Features

    (Not available on all models) Select units have motion detection built into the powerhead. Lights automatically turn ON when motion is detected for much safer movement through the garage. Lights will turn OFF after 4 minutes of no motion. ©2010 The Genie Company 12/2010...
  • Page 4: Table Of Contents

    Troubleshooting Guide - Operation ............. 24-25 Troubleshooting Guide - Powerhead LEDs ..........25 Reference - Wiring Diagram ................26 Warranty ........................27 OPENER MUST BE INSTALLED WITH THE INCLUDED Safe-T-Beam® SAFETY REVERSE SYSTEM MUST BE WALL CONSOLE. INSTALLED TO CLOSE DOOR. ©2010 The Genie Company 12/2010...
  • Page 5: Important Installation Instructions

    There are no assembly or installation steps included in this manual. Contact your Genie® Professional Dealer for an installation poster, if required, or visit www.geniecompany.com to download a PDF file. The following mechanical assembly tasks must be completed before continuing.
  • Page 6: Programming Limits & Force

    ©2010 The Genie Company 12/2010...
  • Page 7 ©2010 The Genie Company 12/2010...
  • Page 8: Contact Reverse Test

    ©2010 The Genie Company 12/2010...
  • Page 9: Program Intellicode® 2 Remote To Powerhead

    ©2010 The Genie Company 12/2010...
  • Page 10: Programming Homelink®, Car2U®, Intellicode® 1 Remotes Or Wireless Keypads

    ©2010 The Genie Company 12/2010...
  • Page 11: Typical Installed Illustrations

    REMARQUE: Utilisez la console sur le mur et les capteurs de sécurité fournis avec cet appareil. NE PAS substituer la console du mur ou les capteurs de sécurité. NOTA: Use la consola de pared y los sensores de seguridad proporcionados con esta unidad. NO sustituya la consola de pared ni los sensores de seguridad. ©2010 The Genie Company 12/2010...
  • Page 12: Typical Sectional Door Installation

    ..........POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONAL ..........PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must reach grounded outlet without use of extension cord.
  • Page 13: Typical One Piece Door Installation

    .....POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE PUERTA DE UNA SOLA PIEZA ........PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must reach grounded outlet without use of extension cord.
  • Page 14: Overview Of Powerhead Controls

    30 seconds if there is no key stroke through menus activity. Open Travel button multi-function; moves door, advances through menus LED Colors Round Red Long Red Round Purple Long Purple Round Blue Long Blue ©2010 The Genie Company 12/2010...
  • Page 15: Overview Of Remotes And Options

    • Re-orient or relocate the receiver antenna. • Increase the separation between the opener and receiver. • Connect the opener into an outlet on a circuit different from that to which the receiver is connected. • Consult your local dealer. ©2010 The Genie Company 12/2010...
  • Page 16: Intellicode® Features

    IntelliCode® 2 openers Use IntelliCode® One or more openers manufactured between 1997 5. Take the remote to the older Genie® garage door and 2010 (IntelliCode® 1) opener and follow that opener's instructions to program a new remote. NOTE: A maximum of 3 different openers can be programmed to a 3 button remote.
  • Page 17: Maintenance & Troubleshooting

    Bestimmungen der USA und Kanadas abweichen. MAINTENANCE & TROUBLESHOOTING FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM If you have any questions, please do not hesitate to contact customer service at: 1-800-35-GENIE IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of severe injury or death: 1.
  • Page 18: Routine Monthly Maintenance

    – Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. FIG. 6-2 2 x 4 under center of door opening ©2010 The Genie Company 12/2010...
  • Page 19: Change Light Bulbs

    RESET - OPEN/CLOSE TRAVEL LIMIT Performing all ten (10) Limits/Force setting steps (pages 6-7) erases previous Limits/Force settings. NOTE: The opener will not close the door automatically unless the Safe-T-Beam® System is installed and Limits are programmed. ©2010 The Genie Company 12/2010...
  • Page 20: Wall Console - Overview

    Wall consoles from other manufacturers may not work with Red indicator light is always ON openers of these serial number groups. Genie® Series I wall buttons and Series II wall consoles will not work with openers When Sure-Lock™ is ON the of this serial number group.
  • Page 21: Remote Battery Replacement

    Replace remote battery with a CR 2032 coin cell battery. 1. Open the remote case using a washer or coin that fits into the slot at the top of the remote. 2. Replace battery. 3. Align components and snap case closed. ©2010 The Genie Company 12/2010...
  • Page 22: Speed Adjustment Guide

    ADJUSTMENT GUIDE - SPEED SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM Speed settings are pre-programmed at the factory CHANGE SPEED SETTING for the maximum speed. Speed settings should not Use this guide to ADJUST powerhead SPEED settings. need adjustment with this unit.
  • Page 23: Force Adjustment Guide

    ADJUSTMENT GUIDE - FORCE SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM CHANGE FORCE SETTING CAUTION Use this guide to ADJUST powerhead FORCE settings. Door closing force is FACTORY set and requires no NOTE: There are nine (9) force levels. adjustment for normal operation.
  • Page 24: Troubleshooting Guide - Operation

    Safe-T-Beam® System completely closed. malfunction. • Check for interference from adjacent Safe-T-Beam® units. • Contact The Genie Company at 1-800-35-GENIE. Door starts down, • Check Safe-T-Beam® wire connections at powerhead. See page 18. then STOPS before it • Check Limits are properly set. See pages 6-7.
  • Page 25: Troubleshooting Guide - Powerhead Leds

    TROUBLESHOOTING GUIDE - OPERATION (CONTINUED) ..............FOR HELP-1-800-35-GENIE PROBLEM WHAT TO DO • Be sure all door fasteners are tight. Noisy operation. • Be sure garage door is in good repair, properly lubricated and balanced. • Be sure opener is in good repair.
  • Page 26: Reference - Wiring Diagram

    ............POUR OBTENIR DE L’AIDE-1-800-35-GENIE REFERENCIA - ESQUEMA ELÉCTRICO DEL CIRCUITO ............PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE Opener circuit wiring diagram. This wiring diagram is for reference only. Schéma de câblage de l’ouvreur. Ce schéma de câblage est indiqué à titre de référence uniquement.
  • Page 27: Warranty

    Genie customer service and provide proof of the date and location of purchase and your identity as the original purchaser of the Product. Call Genie Customer Service toll free at 1-800-354-3643 to speak with a trained representative. Purchaser must allow seller a reasonable opportunity to inspect Product claimed to be defective prior to removal or alteration of its condition.

This manual is also suitable for:

30643064hTrilog 1500 4064

Table of Contents