10-3 TEMPERATURE
CHART - REFRIGERATOR
AND DEFROST SENSOR
-39°F (-40°C)
-30°F (-35°C)
-21 °F (-30°C)
-13°F (-25°C)
-4°F (-20°C)
5°F (-15°C)
14°F (-10°C)
23°F (-5°C)
32°F (O°C)
41 °F (5°C)
50°F (10°C)
59°F (15°C)
68°F (20°C)
77°F (25°C)
86°F (30°C)
95°F (35°C)
104°F (40°C)
225.1 k_
169.8 k_
129.3 k_
99.30 k_
76.96 k_
60.13 k_
47.34 k_
37.55 k_
30 k_
24.13 k_
19.53 k_
15.91 k_
13.03 k_
10.74 k_
8.89 k_
7.40 k_
6.20 k_
4.48 V
4.33 V
4.16V
3.95 V
3.734 V
3.487 V
3.22 V
2.95 V
2.67 V
2.40 V
2.14V
1.89 V
1.64 V
1.45 V
1.27 V
1.10V
0.96 V