Circuit Diagram - LG LRTBC2021BS Service Servicing Precautions

Table of Contents

Advertisement

4-30LP
(OVERLOAD
PROTECTOR)
4-3-1 Definition
of OLP
(1) OLP (OVERLOAD
PROTECTOR)
is attached to the
Compressor and protects the Motor by cutting the
current to the Motor if the temperature
rises and
activates the bimetal spring in the OLP.
(2) When over-voltage flows to Compressor motor, the
Bimetal works by heating the heater inside the OLP,
and the OLP protects Motor by cutting off current which
flows to the Compressor
Motor,
4-3-2 Role of the OLP
(1) The OLP is attached to the Hermetic Compressor
used
for the Refrigerator and prevents the Motor Coil from
being started in the Compressor.
(2) Do not turn the Adjust Screw of the OLP in any way for
normal operation of the OLR
(Composition and connection diagram of OLP)
5. CIRCUIT DIAGRAM
CONTACTING
POINT
COVER
_BIMETAL
BIMETAL
ADJUST
SCREW
HEATER
Figure
21
b'l_gl_ON
NO ON
TIME
SW2
SW3
OFF
OFF
10.5IW
OFF
OFF
9
ON
OFF
10SeC
ON
OFF
11 sec
OFF
ON
12 sec
OFF
ON
t3sec
ON
ON
14 sec
15sec
_0FF
2
3
SW1SW2 SW3
3854JD1046C
-9-

Advertisement