KitchenAid KIRD807HSS0 Installation Instructions And Use And Care Manual page 9

30" and 36" retractable downdraft vent systems

Advertisement

5 mConnect v ent systemto
blower.Ventsystemmustendwith
a wall or roof cap. Useducttape
to sealail joints.
Installcooktopaccording
to manufacturer's i nstructions.
Check that rearof cooktopoverlaps
edgeof retractable downdraftvent
by 3/8"(9.5mm).
To get the most
efficient
use from your
new
retractable
downdra#
vent,
read the Use and Care
information
section
on
page
12.
Keep InstMlation
instructions
and Use and Care
information
close
by for
easy reference.
KIRD and YKIRD
MODELS
ONLY
NOTE: Exterior-mounted
vent
motor installations
require exterior
blower
system, Part No,
KPED892K, available from your
dealer or authorized
parts supplier.
island location
F_
Built-in
cabinet location
Built-in
cabinet location
Roof venting
_J
'".,
10" (25,4 cm)
round
vent
Maximum
_ength of vent
system
Vent
Length
10" (25,4 cm) round
40 ft. (12.2 m)
Vent length
is given
as a general
reference
only. For a longer
vent
run, or smaller
vent system,
contact
a qualified
and trained
vent
installer.
Check with
local
codes
for makeup
air
requirements,
if any.
For best performance,
use no more
than three g0 ° elbows,
if more than
one elbow is used, make sure that
there is a minimum
of 24 inches
(61 cm) of straight
vent between
any two elbows. Do Not install two
elbows together.
it is recommended
that you use
round vent instead of rectangular
vent, especially
if elbows are
required,
if rectangular
vent is
required,
it should be transitioned
to 10" (25.4 cm) round vent as
soon as possible.
Determining
the length
of system
you need:
To calculate the length of system
you need, add the equivalent
feet
for each duct piece that will be
needed. See example
for 10"
(25.4 cm) round vent system.
10" (25.4
era} round
vent
svstem
E
Maximum
mength = 40 ft, (12,2 rn)
2-90elbows
=10
ft.
(3m)
10 ft. (3m) straight=10
ft.
(3m)
Length of 10"
(25.4 cm) system
= 20 ft. (6.1 m)
Note:The
exterior-mounted
vent
motor requires a separate wiring
cable that should
be installed
at
the same time the vent work is
installed.
left vent
right
vent
9