Clearance Between Needle And Hook (No.l) - Kenmore 385.15202400 Service Manual

Table of Contents

Advertisement

SEWING MACHINE DIV. 20
MODEL 385. 15208400
MECHANICAL ADJUSTMENT
CLEARANCE BETWEEN NEEDLE AND HOOK (NO.l)
TO CHECK:
THE CLEARANCE BETWEEN NEEDLE AND SHUTTLE RACE SHOULD BE -0.05 -+0.10MM.
IF NOT, MAKE AN ADJUSTMENT
AS FOLLOWS:
ADJUSTMENT
PROCEDURE:
1.
OPEN THE FACE COVER.
i
2.
SET THE PATTERN SELECT DIAL " C i 3 ", WIDTH SELECTOR DIAL AT" 0 "
3.
LOOSEN SET SCREW (A), AND MOVE THE NEEDLE BAR SUPPORTER TO ARROWS
TO GET CLEARANCE BETWEEN -0.05 TO +0.10MM.
* WHEN CLEARANCE IS TOO WIDE, MOVE THE NEEDLE BAR SUPPORTER TO
DIRECTION (B).
* WHEN CLEARANCE IS TOO NARROW, MOVE THE NEEDLE BAR SUPPORTER TO
DIRECTION (C).
NOTE: AFTER THIS ADJUSTMENT,
CHECK IF THE CLEARANCE BETWEEN NEEDLE
AND NEEDLE PLATE IS MORE THAN 0.15MM AS SHOWN IN FIGURE (D).
IF NOT, ADJUST THE CLEARANCE BETWEEN NEEDLE AND SHUTTLE RACE
BY USING METHOD OF ADJUSTMENT
NO.2 IN PAGE 13 AFTER READJUST THE
CLEARANCE BETWEEN NEEDLE AND NEEDLE PLATE MORE THAN 0.15MM.
SETSCREW_
DIRECTION
B
NEEDLE BAR SUPPORTER
-0.05-+0.
IOMM
CLEARANCE
BETWEEN
NEEDLE AND
NEEDLE PLATE IS MORE THAN
O.15MM
16