POWER
CORD CONNECTIONS
(3-Wire
Connection
Instructions.
For existing
installations
ONLY
-
Refer to Fig. 13).
1.
Follow the manufacturer's
installation
instructions
supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).
2.
Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).
IMPORTANT
NOTE:
DO NOT LOOSEN the factory installed nut
connections
which secure the range wiring to the terminal block.
Electrical failure or toss of electrical connection
may occur if these 3 nuts
are loosened or removed.
3.
Make sure all connections
are tightened securely and replace the rear
access cover (See Fig. 9).
Grounding
Instructions
(3-Wire
Connections
only):
A ground strap is
installed on this range which connects the center terminal of the terminal
block (Neutral) to the range chassis. The ground strap is connected
to the
range by the center, lowest screw (See Fig. 13). The ground strap must not
be removed unless National,
State or Local Codes do not permit use of a
ground strap.
NOTE:
If the ground strap is removed for any reason, a separate ground wire
must be connected to the separate ground screw attached to the range
chassis and to an adequate ground source.
4c. 3 & 4-WIRE
PERMANENTWIRE
CONNECTIONS.
3 - Wire Permanent
Connection
- follow
Steps 1,2 & 5 below.
4 - Wire Permanent Connection
- follow
Steps 1 thru 5 below.
Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):
3-Wire Connection
Connect
line 1
here
Terminal
block
3 Factory installed connections
(DO NOT LOOSEN)
Connect
neutral
(white or
center) here
Connect
line 2
here
Ground screw
& ground I:
NOTES:
Install strain-relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Fig. 13
FOR 3 & 4-Wire Permanent Connections
<-Tighten all 3
Terminal
wire leads
block
1.
(3 & 4 - Wire Permanent
Connections)
Follow the manufacturer's
installation
instructions
supplied with the strain relief and install.
2.
(3 & 4 - Wire Permanent
Connections)
Strip insulation away from the
ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections).
Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).
IMPORTANT
NOTE:
DO NOT LOOSEN the factory installed nut
connections
which secure the range wiring to the terminal block.
Electrical failure or toss of electrical connection
may occur if these 3 nuts
are loosened or removed. NOTE: For 3-Wire Permanent
Connections
skip Steps 3 & 4 and continue with Step 5.
3.
(4-Wire Permanent
Connection
ONLY) Disconnect the ground strap.
Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance.
Cut and
discard the copper strap from the terminal block. KEEP the ground screw,
ground plate and go to Step 4.
4.
(4-Wire Permanent
Connection
ONLY) Connect the ground wire lead
(Green) to the frame of the appliance
using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally
installed.
5.
(3 & 4 - Wire Permanent
Connections)
Make sure all connections
are
tightened securely and replace the rear access cover (See Fig. 9).
NOTE: Non-terminated
field wire compression
connections
must be set at
22 in./Ibs, or greater. Always use 10 gauge wire or larger.
5. CAREFULLY
SLIDE
RANGE
INTO FINAL LOCATION.
Be sure to provide all the adequate clearances and dimensions
shown in Figs.
1, 2 & 3 before moving appliance into final location.
Carefully slide range into final position while inserting rear leveling leg into and
FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7). Make sure the power
cord folds into the remaining open floor area behind the range Warmer or storage
drawer. Be sure to check the level of the range.
4
Line 1
Line 2
plate
screw
Ground
strap
Fig. 14
Note:
Non-terminated
field wire compression
connections
must be set at approximately
22in./
lbs. Always use 10 ga. wire or larger.
GROUND
PLATE
-"_"
GROUND
SCREW
GROUND
LEAD
Serial Plate Locations:
PROPER
GROUND
FOR
4-WIRE
Nb
PERMANENT
Fig. 15
Serial
Serial plate is located on the lower right front frame
of the appliance. Alternate location may be under
cooktop.