2b. MODELS
REQUIRING
POWER
SUPPLY
CORD KIT.
RISK OF FIRE OR ELECTRICAL
SHOCK MAY OCCUR IF AN
INCORRECT
SIZE RANGE CORD KIT IS USED, THE
INSTALLATION
INSTRUCTIONS
ARE NOT FOLLOWED OR
STRAIN RELIEF BRACKET IS DISCARDED.
This appliance
may be connected
by means of a power supply
cord. Only a power supply cord kit rated at 125/250 volts
minimum, and marked for use with ranges shall be used. See
Fig. 10 for cord kit ampere rating information. Cord must have
either three (3) or four (4) conductors
(See Fig. 8). Terminals
on end of wires must be either closed loop or open-end spade
lugs with upturned ends. Cord must have strain relief properly
installed. See Steps 4a. for 4-Wire or 4b. for 3-Wire
connections.
Separate
Strain Relief
before installation
Fig. 11
3. ELECTRICAL
CONNECTION
TO RANGE.
The Rear Access Cover must be removed (Fig 9). To remove,
loosen center screw (one screw) and remove cover. The
terminal block will then be accessible.
3 & 4 - Wire electrical wall Receptacle
types &
recommended
mounting orientation on wall
Required
for new and
remodeled
installations
4-Wire Wall
receptacle
(14-50R)
O
Allowed
for
existing
installations
3 Wire Wall
receptacle
(10-50R)
Fig. 8
NOTE:
Range is shipped from factory with 1-3/8" dia. hole as
shown. To use either 7/8" dia. hole or 1-1/8" dia. knockouts
refer to Fig. 9.
1-1/8" Dia.
7/8" Dia.
Knockout
Hole
(See Chart)
(See Chart)
Mounting
Plate
Rear
Access
Cover
1-3/8"
Pocket
Hole
for Cable
Fig. 9
(See Chart)
Mounting
Plate
Range
Connection
Opening
Size Chart
Supply Cord Kit ampere rating information.
See serial plate on range
for kilowatt
rating
data.
See Serial Plate on Range for
KW Rating
120/240 Volts 120/208 Volts
8.8-16.5
KW
7.9-12.5
KW
16.6-22.5
KW
12.6-18.5
KW
Cord Kit
Ampere
Rating
40/50 Amp
50 Amp
Diameter
(inches)
of Range
connection
Opening
Permanent
Cord Kit
Wiring
1-3/8 in.
1-1/8 in.
1-3/8
in.
I-3/8
in.
Fig. 10
4A. POWER CORD CONNECTIONS
(4-Wire Connection
Instructions - Refer to Fig.12)
Before wiring the range review the suggested
power source
location drawing in Fig. 3. If connecting to a 4-Wire electrical
system (new branch-circuit
or mobile home requires 4-Wire
connection):
1.
Follow the manufacturer's
installation
instructions
supplied with the strain relief and install (Also see Figs. 9,
10 & 11).
2.
Insert the end connectors for Line 1, Line 2 and Neutral
and tighten securely to the terminal block.
IMPORTANT
NOTE: DO NOT LOOSEN the factory installed
nut connections
which secure the range wiring to the
terminal block. Electrical failure or loss of electrical
connection
may occur if these 3 nuts are loosened or
removed.
3.
You must disconnect
the ground strap.
Remove the
factory installed ground screw & plate to release the
copper ground strap from the frame of the appliance.
Cut
and discard the copper ground strap & plate. KEEP the
ground screw.
4.
Connect the ground wire (Green) lead with the eyelet to
the frame of the appliance with the ground screw using the
same hole in the frame where the ground screw was
originally installed (See Fig. 12).
5.
Make sure all screws are tightened securely and replace
the rear access cover (See Fig. 9).
4-Wire Connection
3 Factory installed connections
(DO NOT LOOSEN)
Terminal
block
Connect
line 1
here
Cut ground
strap.
ground strap
& ground plate
Connect g
insulated copper
ground wire with
ground screw here
NOTES:
Install strain-relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Connect
neutral
(white or
center) here
Connect
line 2
here
Fig. 12

Advertisement

loading

This manual is also suitable for:

Ew28bs85ks3Ei23bc65ks3