Vent Products; Listed And Tested Vent Products For The 305 And 505 Models; Flue Terminal Clearances (Ans Z21.10.3 • Csa 4.3) - Kenmore 154.330030 Owner's Manual

305 and 505 series models direct vent tankless water heaters for indoor applications only
Table of Contents

Advertisement

Table 5: Listed and Tested Vent Products
for the 305 and 505 Models
Manufacturer
Ubbink
Heat-Fab
MetaI-Fab
Product
Rolux Vent System
Saf-T Vent SC system
Corr/Guard Vent/Air Intake System
Parts
Refer to the manufacturer's
technical literature for specific part numbers and
instructions.
Vent Manufacturer Contact Information for Installation Instructions and Parts Lists:
Ubbink
Telephone: 866-677-4960
500 Tennessee Waltz Parkway
Ashland City, TN 37015
Heat-Fab
Telephone: 800-772-0739
Fax: 413-863-4803
E-mail: custsvc@heat-fab.com
Web Site: www.heatfab.com
MetaI-Fab Inc.
Telephone: 800-835-2830
316-943-2351
Fax: 316-943-2717
E-mail: info@mtlfab.com
Web Site: www.metal-fabinc.com
Figure
8: Flue Terminal
Clearances
(ANSI
Z21.10.3
• CSA 4.0)
(_)
AtR SUPPLY
INLET
[_]
VENT TERMINAL
_]
REA WHERE
TERMINAL
tS NOT
PERMITTTED
©
©
Ref
A
B
C
D
E
F
G
H
I
J
Clearance
Clearance
Clearance
assembly
Clearance
Description
Clearance
above grade, veranda,
porch, deck, or balcony
Clearance
to window
or door that may be opened
Clearance
to permanently
closed window
Vertical
clearance
to ventilated
soffit, located
above the terminal within a
horizontal
distance
of 2 feet (61 cm) from the center
line of the terminal
Clearance
to unventilated
soffit
to outside
corner
to inside corner
to each side of center line extended
above
meter/regulator
US Installations
12 inches (30 cm)
12 inches (30 cm)
to service
regulator
vent outlet
Clearance
to nonmechanical
air supply inlet to building
or the combustion
air
inlet to any other appliance
Clearance
to a mechanical
air supply inlet
L
Clearance
above paved sidewalk
or paved driveway
located
on public property
M
Clearance
under veranda,
porch,
deck, or balcony
12 inches (30 cm)
3 feet (91 cm) above if within
10 feet (3 m) horizontally
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves
both dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
For clearances
not specified in ANSI Z223.1/NFPA
54 or CSA B149.1, clearances
are in accordance
with local installation codes and the
requirements
of the gas supplier.