Water Piping - Kenmore 153.333931 Owner's Manual

For mobile home
Hide thumbs Also See for 153.333931:
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Water
Piping (cont'd)
• Look at the top cover of the water heater. The water outlet is
marked hot. Put two or three turns of teflon tape around the
threaded end of the I:hreaded-to-sweat coupling and around
both ends of the ¼" threaded nipple. Using flexible connec-
tors, connect the hot water pipe to the hot water outlet of the
water heater.
• Look at the lower right side of the water heater. The cold
water inlet is marked cold. Put two or three turns of teflon
tape around the threaded end of the threaded-to-sweat cou-
plingand around both ends of the ¼" threaded nipple. Using
flexible connectors, connect the cold water pipe to the cold
water inlet of the water heater.
WATER
PIPING
PRESSURE
TEST
This section is only for the mobile home matnufacturer
installing
the water heater when the installation is to comply with H.U.D.
Standards.
When testing the water ways, H.U.D. Standards state:
"Water distribution system. All water piping in the water dis-
tribution system shall be subjected to a pressure test. The test
shall be made by subjecting the system to air or water at I00
psi for 15 minutes without loss of pressure. When air pres-
sure is used, the water heater shall not be connected dur-
ing the test."
NOTE: This water heater is insulated to minimize heat loss
from the tank. Further reduction in heat loss can he accom-
plished by insulating
the hot water lines from the water
heater.
INSTALLATION
COMPLETED
USING
SEARS INSTALLATION
KIT
AWARNING
If the water piping system is to be air pressure test-
ed, the water
heater must be disconnected
from
the water piping system. Failure to disconnect the
water
heater
during air pressure
testing
of the
water piping system could result IN DEATH,
SERI-
OUS BODILY INJURY, OR PROPERTY DAHAGE.
HOT OUTLET
HOT OUTLET
_'l-
_l
TO HOUSE/
THREADED
TO
SWEAT COUPLING
3/4" THREADED_
COUPLINGS
IBLEWATER
CONNECTOR
TEMPERATURE-
PRESSURE
RELIEF VALVE
THREADED
TO
SWEAT
COUPLING
=LEXIBLE
WATERJ
CO NN ECTO/R,/"
/
_.Hv_:
LVOEFF
COLD
INLET
WATER LINE
WHEN
AIR TESTING,
REMOVE THE WATER
LINES FROM THE
WATER HEATER
[]
COLD INLET
(Do
not cap or plug.
Must
terminate
beneath
Mobile
Home)