Installation
Instructions
(cont'd)
Temperature-Pressure
Relief Valve
&WARNING
At the time of manufacture
this water heater was provided
with a combination temperature-pressures relief valve certified
by a nationally recognized testing laboratory that maintains
_riodic inspection of production of listed equipment or mate-
rials, as meeting the requirements
for Relief Valves and
Automatic Gas Shutoff Devicesfor Hot Water Supply Systems,
and the latest edition of ANSI Z21.22 and the code require-
ments of ASME. If replaced, the valve must meet the require-
ments of local codes, but not lessthan a combination tempera-
ture and pressure relief valve certified as meeting the require-
ments for Relief Valves and Automatic Gas Shutoff Devices for
Hot Water Supply Systems, ANSI Z21.22 by a nationally recog.
nized testing laboratory that maintains periodic inspection of
production of listed equipment or materials.
The valve must be marked with a maximum
set pressure not
to exceed the marked hydrostatic working pressure of the
water heater (150 Ibs./sq.in.) and a discharge capacity not less
than the water heater input rate as shown on the model rating
plate. (Electric heaters - watts divided by 1000 x 3415 equal
BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the use of a
temperature-pressure relief valve complying with ANSI Z21.22
and ASME, may require a valve model different from the one
furnished with the water heater.
Compliance with such local requirements must be satisfied by
the installer or end user of the water heater with a locally pre-
scribed temperature-pressure relief valve installed in the desig-
nated opening in the water heater in place of the factory fur-
nishedvalve.
For safe operation of the water heater, the relief valve must not
be removed from it'sdesignated opening or plugged.
The temperature-pressure relief valve must be installed directly
into the fitting of the water heater designatedfor the relief valve.
Position the valve downward and provide tubing so that any dis-
charge will exit only within 6 inches above, or at any distance
below the structural floor Be certain that no contact is made
with any live electrical part. The dischargeopening must not be
blocked or reduced in size under any circumstances. Excessive
length, over 30 feet, or use of more than four elbows can cause
restriction and reduce the dischargecapacity of the valve.
No valve or other obstruction is to be placed between the relief
valve and the _nk. Do not connect tubing directly to discharge
drain unlessa 6 air gap is provided. To prevent bodily injury, haz-
ard to life, or property damage, the relief valve must be allowed
to dischargewater in quantities shouldcircumstancesdemand. If
the dischargepipe is not connected to a drain or other suitable
means,the water flow may causeproperty damage.
The Discharge Pipe:
• Must not be smaller in size than the outlet pipe size of the
valve,or haveany reducing couplingsor other restrictions.
• Must not be plugged or blocked.
i • Must be of material listed for hot water distribution.
• Must be installed so as to allow complete drainage of both
the temperature-pressure
relief valve, and the discharge
pipe.
• Must terminate at an adequate drain.
• Must not have any valve between the relief valve and tank.
I
AWARNING
The temperature-pressure
relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (I) no one is in front of or around the outlet of
the temperature-pressure
relief valve discharge line, and (2)
the water manually discharged will not cause any bodily
injury or property
damage
because the water
may be
extremely hot,
If after manually operating the valve, it fails to completely
reset and continues to release water, immediately close the
cold water inlet to the water heater, follow the draining
instructions, and replace the temperature-pressure
relief
valve with a new one.
HOT
PRESSURE
RELIEF VALVE
SHUTOFF
VALVE
SCHARGE
PIPE
(Do not cap or
plug. Must termi-
nate beneath
Mobile Home.)
RELIEFVALVEOPENING
"THISWATERHEATER IS PROVIDED WITHA COMBINATION T EMPER-
ATURE-PRESSURE R ELIEFVALVE.FOR SAFEOPERATION OF THE
WATERHEATER,THE RELIEF VALVE(S)MUSTNOT BE REMOVED
FROMITSDESIGNATED P OINTOF INSTALLATION O R PLUGGED."
YOURLOCALJURISDICTIONAL A UTHORITY, WHILEMANDATING THE
USEOF A TEMPERATURE-PRESSURE RELIEFVALVECOMPLYING
WITHANSIZ21.22AND ASME,MAYREQUIREA VALVEMODELDIF-
FERENTFROMTHEONEFURNISHED WITHTHEWATER HEATER.
COMPLIANCE WITHSUCHLOCALREQUIREMENTS MUSTBE SATIS-
FIEDBY THE INSTALLEROR END USEROF THE WATERHEATER
WITHA LOCALLYPRESCRIBED TEMPERATURE-PRESSURE
RELIEF
VALVEINSTALLEDIN THE DESIGNATED OPENINGIN THE WATER
HEATER.
SEE MANUAL HEADING--"TEMPERATURE-PRESSURE RELIEF
VALVES" FORINSTALLATION A ND MAINTENANCE OF RELIEFVALVE,
DISCHARGE LINEANDOTHERSAFETYPRECAUTIONS.
13