Please checkthefollowing before calling forservice:
Place onecupof waterin a glassmeasuring c upinthemicrowave ovenandclosethedoorsecurely.
Operate the microwave ovenforoneminute at HIGH 100%.
A Doesthe microwave ovenlightcomeon?
B Doesthecooling fanwork? (Putyourhand attopaboveDisplay.)
C Doestheturntable rotate? (Itis normal f ortheturntable toturnineitherdirection.)
D Isthewaterinthemicrowave o venwarm?
YES
NO
YES
NO
YES
NO
YES
NO
If "NO" is theanswertoany
of the above questions,
please check electrical
outlet,
fuse and/or circuit
breaker. If they are functioning
properly,
CONTACT
YOUR NEAREST
ELECTROLUX
AUTHORIZED
SER-
VICER.
A microwave
oven should
never be serviced
by a
"do-it-yourself"
repair person.
1. If time appearing in the display is counting down
very rapidly, check Demonstration
Mode on page 22
and cancel.
2. If the oven is set for more than 40 minutes at 80,
90 or 100 percent power level, after the first 40
minutes the power level will automatically adjust
itself to 70 percent power to avoid overcooking.
AC Line Voltage:
Single phase 120V, 60Hz, AC only
AC Power Required:
1500W 13.5 amps. (for FFMV154CLS, FFMV152CLB/W
CFMV154CLS, CFMV152CLB/W)
Output Power*:
900 W
Output Power*(convection):
1450 W
Frequency:
2450 MHz (Class B/Group2)**
Outside Dimensions (including handle):
29.88 "(W) x 15.75 "(H) x 15.04
"(D)
Cavity Dimensions:
20.24
"(W) x 8.94 "(H) x 14.41
"(D)
Microwave oven Capacity***:
1.5 Cu.Ft.
Cooking Uniformity:
Turntable
Weight:
Approx. (net) 55.1 Ib, (gross) 62.8 Ib
Work/Night Light:
2 bulbs 30w each (incandescent light bulbs)
Oven Light:
1 bulb 30w (incandescent
light bulbs)
*
The International Electrotechnical Commission's standardized method for measuring output wattage. This test method
is widely recognized.
**
This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard ClSPR11.
***
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC
Federal Communications
Commission Authorized.
DHHS
®
CQUS
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters Laboratories,
Inc.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in
USA or Canada.