Alarm Functions; Control Lockout; Sabbath Mode; Manual Defrost - Frigidaire GLFH17F8HWF Guide Manual

Electronics control
Table of Contents

Advertisement

Available languages

Available languages

CONTROL L OCKOUT
Thisfeature prevents s omeone f romaccidentally c hanging
thetemperature andExtreme Freeze settings. Toactivate
thecontrol l ockout, p ress andholdtheControl L ockbutton
forthreeseconds. "LO" (seeFigure 5) willbedisplayed f or
3 seconds indicating t hatthecontrol panelis locked. "LO"
willbedisplayed ifanybutton is pressed. Tocancel C ontrol
Lockout, pressandholdtheControl L ockbutton forthree
seconds. When the lockout i scancelled, "UI"(seeFigure
6) willdisplay for3 seconds, andthenshow thecurrent
temperature s etting.
i
,,'_'_
_
extreme
temp
atarm
controt
i
m
freeze
display
reset
lock
Door Ajar
Power
Loss
hold
for F/C o
Figure 5
f
...................................................................................................................................................................................................................................................................
\
extreme
temp
alarm
control
freeze
display
reset
lock
DoorAjar
Power Loss
hold for F/Co
j
Figure 6
SABBATH MODE
Sabbath mode provides the ability to disable all lights and
other electrical activity from occurring with the exception of
the compressor, which continues to operate automatically.
Sabbath mode is started or stopped by pressing the
Control Lock and Temp Display buttons at the same time
and holding for three seconds. When started, "Sb" will
be displayed for one second and then the display will
turn off. When the Sabbath Mode is stopped, the current
temperature setting will be displayed and all functions
resume normal operation.
MANUAL DEFROST
Manual defrost will force the freezer to enter an im-
mediate defrost cycle. The mode can be started or stopped
by pressing the Extreme Freeze and Alarm Reset buttons
at the same time for five seconds. When active, "dE" is
displayed. After thirty minutes, the cycle will complete and
the freezer will display the current temperature setting and
resume normal operation.
TEMPERATURE
ALARM
If the cabinet temperature rises to a level above 23°F
(-5°C), the "Hi Temp" display indicator will illuminate. If the
temperature stays above 23°F (-5°C) for more than one
hour, a high temperature alarm will also be activated. The
control panel will beep every 5 seconds. You may stop the
beep by pressing the Alarm Reset button. The Hi Temp
display indicator will continue to be displayed until the
problem is determined, corrected and temperature once
again drops to a level below 23°F (-5°C). During the high
temperature condition, the display will show the actual
internal temperature until the set temperature is once
again reached. The display will then show only the set
temperature.
DOOR AJAR ALARM
The door alarm will activate if the door is open for more
than five minutes. There will be an audible beep every five
seconds and the "Door Ajar" indicator will illuminate. Press
the Alarm Reset button to turn the audible alarm (beep)
off. The "Door Ajar" indicator will remain on until the door is
closed. If the door remains open, audible alarm will sound
again after five minutes. If the door remains open for 15
minutes, the interior light will shut off.
POWER FAILURE
When power to the freezer is restored after the occur-
rence of a power failure, the "Power Loss" LED will be
illuminated.
If the internal temperature of the freezer has risen to
a temperature greater than 23°F (-5°C), the "Hi Temp"
display indicator will also be illuminated and there will
be an audible beep every five seconds. Press the Alarm
Reset button to turn the audible alarm (beep) off.
If this condition persists, the "Duration" indicator will
also be illuminated and the display will show how many
hours (up to a period of 99) the internal temperature has
been above 23°F (-5°C). Food quality is considered to be
impaired at temperatures greater than 23°F (-5°C). It is left
to the user's discretion to decide how to best manage the
contents within the freezer.
SYSTEM ERROR ALARMS
If "E7", "E8", or "E9" are shown on the display every half
second and the control panel beeps every five seconds,
call service repair to correct the problem. Press the Alarm
Reset button to turn the audible alarm (beep) off. Until
changes are made, freezer will continue to run.
extreme
temp
alarm
control
freeze
display
reset
lock
V
Door
Ajar
Power
Loss
hold for F/C o
j
F:igure 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fkfh21f7hwa