DETERMINE AMOUNT OF DOMESTIC HOT WATER NEEDED, THEN USE THE CHART BELOW TO OPTIMIZE SUPER STOR CONTENDER V.S. BOILER SIZING. NOTE: MINIMUM BTU/H REQUtRED TO ACHIEVE FIRST HOUR RATING THE MASS OF THE BOILER WILL EFFECT RECOVERY TIME, MORE BOILER MASS EQUALS LONGER RECOVERY TIME.
A water heater should always be located in an area with a floor drain or installed in a drain pan suitable for water heaters. Under no circumstances, shall Heat Transfer Products Inc. be held liable for any such water damage whatsoever. This water heater must not be located near flammable...
Page 5
IDANGER? Water temperature over 125° F can cause severe burns instantly, or death from scalds. Children, disabled, and elderly are at highest risk of being scalded, see instruction manual before setting temperature at water heater! Feel water before bathing or showering.
PRESSURE DROP SIZING FOR CIRCULATOR You must have a flow rate, from chart, on the boiler circulator for the boiler water; or the published ratings cannot be achieved. The chart below represents the tube run and the water heater, heat exchanger ONLY, and does not include any flow checks or zone valves or friction loss through the boiler.
Page 7
TYPICAL INSTALLATION USING CIRCULATORS HOTT [COLD IT IS RECOMMENDED THAT 1" LINES USED FOR SUPER STORZONE. SUPER STOR LONG ELEMENT T & P VALVE CONTENDER Indire_Fired Tank TANK CIRCULATOR 24v._iring BOILER CONTROL 110v. wiringl_} LRNPT TO I"SWEAT COUPLINP° BOILER RETURN NOTE: RECOMENDED MXING...
Page 8
SUPER STOR CONTENDER WITH STORAGE TANK TYPICAL INSTALLATION COLD WATER SUPPLY 1TRI _ u_EECDOFMo_NuDpE_RT_TAOT;_INES iT T I COLD HOT TO CB OR stT°=''"g' it,nk-_'-_. inlet valve I ¢lrculltor OONTRQL " v,.,°0 ._.___pDRA,. 8. drain NOTE: IF A SACKFLOW PREVENTER OR A NO RETURN VALVE IS INSTALLED, THERMAL...
Page 9
TYPICAL STEAM BOILER SYTEM SUPPLY HOT T I SOLO LONG ELEMENT WATER LINE & P VALVE Indirect Fire STEAM BOILER CONDENSATE RETURN STR._JN ER l _._T a nk =_DRAIN NOTE: WATER LINE MUST REMAIN ABOVE BOILER OUTLET TO WATER HEATER AT ALL TIMES! LP-65 PAGE: 8...
Page 10
ZONING WITH CIRCULATORS USING R8182D AND R845A RELA_ LzIOOO TANK RB'iE2B N 84_A BURNER IGNITION WATER CfRCULATOR :B.EW ;CONTACT_ CIRCULATOR TANK J_l, 120 Vac POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TO ADDITIONAL THERMOS;TAT HEAT ANTICIPATOR ZONES 3.4.
Page 11
_lJl_tl_l) Im]r_4[_7.,_Lv_[,. "] USING L8148A OR L8152A COLD START BOILER CONTROL WITH CIRCULATORE TO AD DITIO NAL POWER SUPPLY :iT t LIMIT CONTROL 9@0( CIRCULATOR PROVIDE DISCONNECT MEANS OVERLOAD PROTECTION REQUIRED USING L8143A OR L8152A COLD START BOILER CONTROL WITH ZONE VALVE-'= ZONE VALVE WIRING...
Page 12
WHEN RAISING TANK TEMPERATURE, YOU INCREASE THE RISK OF SCALDING - PLEASE USE A | CONFORMANCE. SEE PAGE 7. FOR EXAMPLE, MANUFACTURED HEAT TRANSFER PRODUCTS, INC.; P.O. BOX 429, 120 BRALEY ROAD; EAST FREETOWN, MA 02717; 1-800-323-9651 OR VISIT OUR WEBSITE: WY_N.HTPRODUCTS.COM LP-65 PAGE: 11 REV.: 6/1/01...