MAINTENANCE
INSTRUCTIONS
for
APRILAIRE
HUMIDIFIER
MODEL
440
CAUTION!
Sudden operation may cause personal injury or property damage. Turn
humidistat to "off" or lowest setting before servicing.
1. Note humidistat setting and turn dial to the "Off" position.
2. Remove two aluminum knobs (1), swing up and remove top cover (2) from
humidifier.
3. Place finger under white plastic water outlet (3) at top of black water distribution
pan (4). Lift up to pop outlet loose from hole and notch in black distribution pan.
4. Tip forward and lift the complete plastic framed evaporative assembly out of thq
humidifier.
5. To remove
black plastic water distribution
pan from evaporative
assembly
push down on pan and out on white plastic frame (Scale Control Insert). Clean "V"
openings
in water distribution
section of upper housing but do not scrape off
granular coating from bottom. This helps to ensure proper even water flow for
maximum performance.
6. Remove Water Panel evaporator from Scale Control Insert and clean Insert by flexing
or using putty knife. Inspect Water Panel evaporator (Stock No. 12) and replace if
necessary with colored spot up. Snap plastic water distribution pan back in place.
7. Reinstall evaporative section
in the humidifier with notch
and hole in black
plastic
water
distribution
pan
toward you. Pop nozzle fit-
ting on end of feed tube into
black plastic water distribu-
tion pan.
8. To reinstall top cover, hook
back under lip of metal frame
(5), drop in place and tighten
two aluminum knobs.
9. Remove drain hose and flush
with water under pressure.
Lime in hose may be loos-
ened by flexing hose.
10. Reattach drain hose.
MODELS
440, 448 & 445
11. Turn up humidistat to highest
setting
and make sure the
furnace blower is operating.
Humidifier will operate if RH
is less than 50%.
12. Set humidistat to its original position.
1. Cover Knob
2. Top Cover
3. Feed Nozzle
4. Distribution Tray
5. Metal Frame
MAINTENANCE
INSTRUCTIONS
for
APRILAIRE
HUMIDIFIER
MODELS
448-445
WARNING? 120 volts may cause serious injury from elec13ical shock. Disconnect
power and shut off water supply before servicing.
1. Note humidistat or control setting and turn dial to the "Off" position.
2. Disconnect electrical power and turn off water supply.
3, Remove two aluminum knobs (1), swing up and remove top cover (2) from humidifier.
4. Place finger under white plastic water outlet (3) at top of black water distribution pan
(4). Lift up to pop outlet loose from hole and notch in black distribution pan.
5. _p forward and liftthe complete plasticframed evaporativesection out of the humidifier.
6. To remove black plastic water distribution pan from evaporative section, push down
on pan and out on white plastic frame (Scale Control Insert). Clean "V" openings in
water distribution panel but do not scrape coating off bottom surface.
7. Remove Water Panel evaporator and Scale Control Insert. Remove Water Panel
evaporator from Insert and clean insert by flexing or using putty knife. Inspect Water
Panel evaporator and replace with a new Water Panel evaporator, if necessary, with
colored spot up.
8. Re-instafl black water distribution pan. Reinstall evaporative section in the humidifier,
with notch and hole in distribution pan toward you. Pop hose fitting on end of feed
tube into distribution pan.
9. Sea page 12 for reservoir and pump cleaning.
-11
-