Models 110 & 112 - Aprilaire 1606X Series Owner's Manual

Portable
Table of Contents

Advertisement

MAINTENANCE
INSTRUCTIONS
for
APRILAIRE HUMIDIFIER
MODELS 110-112
WARNING! 120 volts may cause serious injuryfrom electrical shock. Disconnect
power and shut off water supplybefore servicing.
1. Water Supply Line
2. Feed Tube
3. Swing Locks
4. Closure Clip
5, Closure Clip
6, Distribution Pan Cover
1. Disconnect electrical power and turn off water supply.
2. Disconnect: a) 120 volt electrical service, b) Copper water supply line
(1) & feed tube (2). c) Drain line. d) 24 volt leads.
3. Tum two swing locks (3), one at either side of lower housing off humidifier
flange.
4. Lift humidifier straight up Until bottom of unit clears lip of lower housing.
Pull unit out at bottom, lower and remove.
5. Slide off three closure clips (4 & 5) that holds 2 halves of unit together.
6. Remove upper half of unit.
7. Remove Water Panel evaporator
and Scale Control
Insert. Remove
Water Panel evaporator from Insert and clean Insert by flexing or using
putty knife. Inspect Water Panel evaporator
and replace with a new
Water Panel evaporator (Stock No. 10 for Model 110 and Stock No. 12
for Model 112), with colored spot up.
8. Remove the plastic drain hose from the bottom of the unit and bend
and flex it to loosen the internal calcium
deposits. Then flush it with
water under pressure and slip it back onto the black drain fitting.
9. Remove the water distribution
pan cover (6) and clean "V" openings
in water distribution
section but do not scrape off granular coating
from bottom. This helps to insure proper, even water flow for maximum
performance. See page 2 if removed.
10. Oil motor with 2 drops of SAE 20 oil in oil holes at each end of motor
housing.
11. IMPORTANT:
When installing Scale Control
Insert and Water Panel
evaporator
in the humidifier,
the Insert spout must discharge
directly
into unit drain.
12. Reassemble
unit, position
feed tube in compression
fitting, tighten
compression
nuts and secure copper feed tube to upper housing with
feed tube clamp.
13. In reverse order, complete steps 1 and 4 to reinstall your humidifier,
and check unit operation.