Download Print this page

Advertisement

Quick Links

APRILAIRE HUMIDIFIER MODELS 448-445A-445
WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply
before servicing.

Maintenance Instructions

1.
Note humidistat or control setting and turn dial to the "Off" position.
2.
Disconnect electrical power and turn off water supply.
3.
Remove two aluminum knobs (1), swing up and remove top cover (2) from humidifier.
4.
Place finger under white plastic water outlet (3) at top of black water distribution pan (4). Lift up to pop outlet loose
from hole and notch in black distribution pan.
5.
Tip forward and lift the complete plastic framed evaporative section out of the humidifier.
6.
To remove black plastic water distribution pan from evaporative section, push down on pan and out on white plastic
frame (Scale Control Insert). Clean "V" openings in water distribution panel but do not scrape coating off bottom
surface.
7.
Remove Water Panel evaporator and Scale Control Insert. Remove Water Panel evaporator from Insert and clean
insert by flexing or using putty knife. Inspect Water Panel evaporator and replace with a new Water Panel evaporator,
if necessary, with colored spot up.
8.
Re-install black water distribution pan. Reinstall evaporative section in the humidifier, with notch and hole in
distribution pan toward you. Pop hose fitting on end of feed tube into distribution pan.
9.
See below for reservoir and pump cleaning.
MAINTENANCE INSTRUCTIONS
for
Key
1.
Cover Knob
2.
Top Cover
3.
Feed Nozzle
4.
Distribution Tray
5.
Metal Frame

Advertisement

loading

Summary of Contents for Aprilaire 448

  • Page 1: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS APRILAIRE HUMIDIFIER MODELS 448-445A-445 WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. Cover Knob Top Cover Feed Nozzle Distribution Tray Metal Frame Maintenance Instructions Note humidistat or control setting and turn dial to the "Off" position.
  • Page 2 MAINTENANCE INSTRUCTIONS FOR MODELS 445A-445 RESERVOIR PUMP SECTIONS WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. IMPORTANT: Clean and refill reservoir, hose, pump and float every 30 days during heating season. Pump Impellor Cap Cap Flow Control Opening Cap Sides...
  • Page 3 Work arm mechanism (6) up and down to dislodge any scale buildup. TO OIL MOTOR Disconnect water line at valve inlet and swing line free. Disconnect the humidistat leads. Remove the three screws from the brown motor cover and remove. Use two drops SAE 20 oil in the yellow hole on top and inside the yellow mark on the side of the motor.

This manual is also suitable for:

445a445