Troubleshooting - Generac Portable Products 3500PSI 1540-1 Owner's Manual

Hide thumbs Also See for 3500PSI 1540-1:
Table of Contents

Advertisement

Available languages

Available languages

Generac Portable Products 3500 PSIPressure Washer
TROUBLESHOOTING
Problem
Pump
has following
problems:
failure
to produce
pressure,
erratic
pressure,
chattering,
loss of pressure,
low water
volume.
Detergent fails to mix with
spray.
Engine shuts down during
operation.
Cause
I.
Low pressure spray tip installed.
2.
Water inlet isblocked.
3.
Inadequate water supply.
4.
Inlet hose is kinked or leaking.
5.
Clogged inlet hose strainer.
6.
Water supply is over 100°F.
7.
High pressure hose is blocked or
leaks.
8.
Gun leaks.
9.
Spray tip is obstructed.
10. Pump is faulty.
I.
Detergent siphoning tube is not
submerged.
2.
Chemical filter is clogged or
cracked.
3.
Dirty in-line filter.
4.
Low pressure spray tip installed.
Out of gasoline.
Correction
I.
Replacespray tip with high pressure
spray tip.
2.
Clear inlet.
3.
Provide adequate water flow.
4.
Straighten inlet hose, patch leak.
5.
Check and clean inlet hose strainer.
6.
Provide cooler water supply.
7.
Clear blocks in outlet hose.
8.
Replace gun.
9.
Clean spray tip.
10. Contact Authorized
service facility.
I.
Insert detergent siphoning tube into
detergent.
2.
Clean or replace fitter/detergent
siphoning tube.
3.
See"Check In-LineFilter".
4.
Replacespray tip with high pressure
spray tip.
Fill fuel tank.
i
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

1540-1

Table of Contents