Troubleshooting - Generac Portable Products 2400PSI Owner's Manual

2400psi high pressure washer
Hide thumbs Also See for 2400PSI:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

Problem
Pump has following
problems: failure to
produce pressure, erratic
pressure, chattering, loss
of pressure, low water
volume.
Detergent fails to mix
with spray.
Engine runs good at no-
load but "bogs" when
load is added.
Engine will not start; or
starts and runs rough.
Engine shuts down during
operation.
Engine lacks power.
Engine "hunts" or falters.
Generac Portable Products 2,400 PSI High Pressure Washer
Cause
1.
Nozzle in low pressure mode.
2.
Water inlet is blocked.
3.
Inadequate water supply.
4.
Inlet hose is kinked or leaking.
5.
Clogged inlet hose strainer.
6.
Water supply is over 140°F.
7.
High pressure hose is blocked or
leaks.
8.
Gun leaks.
9.
Nozzle is obstructed.
10. Pump is faulty.
1.
Detergent siphoning tube is not
submerged.
2.
Chemical filter is clogged.
3.
Dirty in-line filter.
4.
Nozzle is in high pressure mode.
Engine speed is too slow.
1.
Low oil level.
2.
Dirty air cleaner.
3.
Out of gasoline.
4.
Stale gasoline.
5.
Spark plug wire not connected to
spark plug.
6.
Bad spark plug.
7.
Water in gasoline.
8.
Overchoking.
9.
Excessively rich fuel mixture.
10. Intake valve stuck open or closed.
11. Engine has lost compression.
1.
Out of gasoline.
2.
Low oil level.
Dirty air filter.
Choke is opened too soon.
Correction
1.
Pull nozzle backward for high pressure
mode.
2.
Clear inlet.
3.
Provide adequate water flow.
4.
Straighten inlet hose, patch leak.
5.
Check and clean inlet hose strainer.
6.
Provide cooler water supply.
7.
Clear blocks in outlet hose.
8.
Replace gun.
9.
Clean nozzle.
10. Contact Generac service facility.
1.
Insert detergent siphoning tube into
detergent.
2.
Clean or replace filter/detergent
siphoning tube.
3.
See "Check In-Line Filter" on page 13.
4.
Push nozzle forward for low pressure
mode.
Move throttle control to FAST position. If
engine still "bogs down", contact Honda
service facility.
1.
Fill crankcase to proper level.
2.
Clean or replace air cleaner.
3.
Fill fuel tank.
4.
Drain gas tank; fill with fresh fuel.
5.
Connect wire to spark plug.
6.
Replace spark plug.
7.
Drain gas tank; fill with fresh fuel.
8.
Open choke fully and crank engine.
9.
Contact Honda service facility.
10. Contact Honda service facility.
11. Contact Honda service facility.
1.
Fill fuel tank.
2.
Fill crankcase to proper level.
Replace air filter.
Move choke to halfway position until
engine runs smoothly.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1537-0

Table of Contents