Troubleshooting tips.
ge.com
Troubleshooting -tips.
Save time and money!
Air conditioner
doesnotstart
Possible Causes
The air conditioner
is unplugged.
The
fuse
is blmm/circuit
breaker
is tripped.
Power
failure.
What To Do
"Make
sure the air conditioner
l)lug is l)ushed
completely
into the outlet.
• Check
the house fllse/drcuit
1)reaker box and replace
the fllse or reset the breakeL
• The unit will automatically
re-start in the settings
last
used after the power is restored.
• There is a promctive
time delay (al)l)roximately
3 minums)
to prevent
tripping
_ff the compressor
overload.
For
this reason,
the unit may not start nomml
cooling
fin.
3 minums
after it is turned
back on.
The
current
interrupter
• Press
the
RESETbutton
located
on the power
cord
plug.
device
is tripped.
• lithe
RESETbutton
will not
stay enoa,_ed
discontinue
use of the
air con(litioner
and
contact
a qualified
service
tech nicia
n.
Air conditioner
does
not
Airflow
is restricted.
• Make
sure
there
are no curtains,
blinds
or flJrniture
cool as it should
blocking
the
fl'ont
of the air c_m(lifi(me_:
The
temp
control
may not
• In
COOL
mode,
press
the
DECREASE
Wpad.
be set correctly.
The
air Filter is dirty.
• ( ,'lean the filter
at least
eve_)' 30 days.
See the
OperatingInstructions
secti(;n.
The
room
may have
been
hot.
• X_]mn
the air conditioner
is tilst
turned
on, you
need
to
allow
tillle tor
the
1"00111 to
CO01
dowu.
Cold
air is escaping.
" Check
tot
ol)eu
flu'uace
floor
registels
and
cold
air
I'ett/YUS.
• Set the
air conditioner's
vent
to the
closed
position.
Cooling
coils
have iced
up.
• See "Air conditioner
freezinglip"
below.
Air conditioner
Ice blocks
the air flow mad
• Set the
coutrols
at HIGH
(F3)
FAN or HIGH
(F3)
COOL and
freezing
up
stops
the air conditioner
set the
them/ostat
to a higher
teml)erature.
from
cooling
the
room.
Theremote control
The
batteries
are hlserted
• Check
the
position
of the
batteries.
They
shotfld
be
is not working
incorrectly,
inserted
in the
opposite
(+) and
(-)
direction.
The
batteries
may be dead.
"Replace
the
batteries.
Water drips outside
Excessively hot mad
• This is mmnal.
hmnid
weather.
Waterdrips
indoors
The
air conditioner
is not
• For ln'oper
water
disposal,
make
sure
the
air conditioner
tilted
to the
outside,
slants
slightly
fl'om
the
case fl'ont
to the
re:u:
Watercollectsin
basepan
Moisture
is removed
from
indoor
air mad drains
into
rear
of a cabinet
where
a fan
blows
it against
the outdoor
condenser
coil.
" This is nomml
fin" a short period
in areas with little
humidit},;
nom/al
fin" a longer
period
in ve_' humid
areas.
TIMER feature not
A power
outage
or interruption
•/n
the
case (ff a power
outage
or interrtq)tion,
the
unit
working
properly
occurred.
TIMER teature
will reset
to the
original
setfiu
, x_)t! may
need
to set a new time
if desired.
]3