GE AZ38H09EACM2 Owner's Manual And Installation Instructions page 15

Zoneline air conditioners heat/cool model 2800 heat pump model 3800

Advertisement

Installation
Instructions
265 VOLT ELECTRICAL SUPPLY
/k WARNING:
Connection
of this 265 V AC product
to a branch
circuit
MUST be done
b) direct
connection
in accordance
with
the National
Electrical
Code. Plugging
this unit into a
building
mounted
exposed
receptacle
is not permitted
b) code.
These
models
must be installed
using the ai)propriate
GE power supi)l } kit tor the branch
circuit
amperage
and the electrical
resistance
heater
wattage
desired.
Use the POWER
CONNECTION
CHART on page 17
to determine
the correct
kit required.
One of the
following
installation
methods
(A or B)
must be used.
HOW TO CONNECT
1
Remove
the
room
cabinet.
2
Connect
to electrical
power,
3 See
the
special
instructions
below
fi}r applicable
supply
voltages.
4
Reinstall
the
room
cabinet.
A. FOR SUBBASE INSTALLATION
Electrical subbase kits are a_ailable to provide a flexible
enclosure
fi)r direct
connection,
Branch Circuit and
Proper GE
Power
Unit Amperage Rating
Subbase Kit
Supply Kit
15
ILM4204E 15
ILM(5172
20
IL_K204E20
1L_I(5202
30
IL_K204E30
1L_I(5302
The instructions
pr{Mded wifll the selected subba_
kit must
be cm'efid b tbllo_vvd. It is the responsibilit)
of the installer
to ensure the connection
of COlnponents is done in
accordance
with these insu'ucfions
and all elecu'ical codes.
B. FOR DIRECT CONNECT
INSTALLATION
If an electrical
subbase is not used, direct connection
t()
branch
circuit wiring inside the provided junction
box must
be done in accordance
with the following steps.
I
[] REMOVE JUNCTION
BOX
1 Remo_e
tbe.jm_ction
box cover b) removing
the
l-roi]t two screws.
2 Remo_e
tbejm_ction
box by removing
the top and
bottom
rear screws. Note
bow the tabs on the lower
left side of the jm_ction box se,we to bold the side in
place. This wi!l help when the box is being reinsm!led.
Unitconnector
Junction
Junction
boxcover
box
[] CUT AND STRIP THE CORDSET
1 I-_,emove the cordset
ti'om
the power
supply
kit.
Measure
G" down the cord fl'om where
it elnerges
fix)in the back of the nylon
plastic
connector
and cut the cord
througl]
at this point,
2 Careflfllv
relnove
3" of the cordset
insulation
so as to expose
the three
insulated
wires.
3 Strip
3/4"
of the insulation
away at the end
of each of the three
wires
(i.1, Neutral
and
Ground).
Plug the connector
fldlv into place
in the unit mating
connector.
Be sure
the
locking
tabs at the sides are engaged.
3/4"
I
NOTE:
Order
Kit RAK4002(A,_
to enable
a quick
I
disconnect
inside
the junction
box.
I
15