Performance Data Sheet - Monogram ZFGB21HXCSS Owner's Manual

Double door, double drawer stainless steel free-standing refrigerators
Table of Contents

Advertisement

Performance Data Sheet
GESmartWater Filtration System
G WF Cartridge
Health
Claim Performance
Certified
by NSF/ANSI*
_100% safety
factors
built in for unmetered
usage)
Parameter
Chlorine
r&O
Particulate**
USEPA
MCL
Standard
No. 42: Aesthetic
Effects
Influent
Challenge
1.9 ppm
200,000
Effluent
Average
0.02 ppm
3,978
Maximum
0.05 ppm
7,800
% Reduction
Average
Minimum
98.90%
97.37%
98.00%
96.10%
Para meter
Turbidity
Cgsts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
2,4-D
Asbestos
USEPA
MCL
! NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard
No. 53: Health
Effects
Influent
Effluent
Average
0.07 NTU
26
i ppb
1.8ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFL/ml
Maximum
0.! NTU
55
! ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFL/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
Challenge
24.3 NTU
105,750
!60 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFL/ml
% Reduction
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
* Tested using a flow rate ofO.5 gpm (1.8927
I/m); pressure
of 120 psig (8.437 kg/cm 2); pH of 7.5+_0.5; temp. of 680+_4.5 ° F (200+_2.5° C)
** Measurement
in particles/ml
*** NTU = Nephelometric
Units
Operating
Specifications
• Capacitg: certified for up to 500 gallons (1893 liter); up to one gear
Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33°-100 ° F (0.60-38° C)
Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions; parts and service availabilitg; and standard warrantg are included with the product when shipped.
This drinking water sgstem must be maintained according to manufacturer's instructions, including replacement of
filter cartridges.
Do not use with water that is microbiologicallg unsafe or of unknown qualitg without adequate disinfection before or after
the sgstem. Sgstems certified for cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
The contaminants or other substances removed or reduced bg this water treatment sgstem are not necessarilg in gour water.
Check for compliance with the state and local laws and regulations.
Sgstem
Tested and Certified
bg NSF International
against
ANSI/NSF
Standard 42 & 53 for the reduction of:
Standard No, 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction, Class I
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrozine Reduction
Lindone and 2,4-D Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cgst and Asbestos Reduction
Manufactured for: General ElectricCompang, Louisville,KY40225
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zfgb21hxassZfgp21hxcssZfgp21hxass

Table of Contents