Installing the water line.
Read these instructions completely and carefully.
If the water supply to the refrigerator
is from a Reverse Osmosis Water Filtration
System and the refrigerator is equipped with a built-in filtration system, it is not
necessary to use the refrigerator's
water filter. Use the refrigerator's
Filter Bypass
Plug. Using the refrigerator's
water filtration cartridge in conjunction
with the RO filter
can result in hollow ice cubes and slower water flow from the water dispenser.
This water line installation is not warranted by the refrigerator or icemaker manufacturer.
Follow these instructions
carefully to minimize the risk of expensive water damage.
Water hammer (water banging in the pipes) in house plumbing can cause damage
to refrigerator parts and lead to water leakage or flooding. Call a qualified plumber
to correct water hammer before installing the water supply line to the refrigerator.
Toprevent burns and product damage, do not hook up the water line to the
hot water line.
If you use your refrigerator before connecting the water line, make sure the
icemaker feeler arm is kept in the STOP (up) position.
Do not install the icemaker tubing in areas where temperatures fall below freezing.
When using any electrical device (such as a power drill) during installation, be sure
the device is insulated or wired in a manner to prevent the hazard of electric shock.
All installations must be in accordance
with local plumbing code requirements.
What YouWill Need
To determine how much copper tubing you need."
Measure the distance from the water valve on the back of the refrigerator to the water
supply pipe. Then add 8 feet (244 cm). Be sure there is sufficient extra tubing [about 8
feet (244 cm) coiled into 3 turns of about 10 inches (25 cm) diameter] to allow the
refrigerator
to move out from the wall after installation.
:_ A water supply kit (containing copper robing, shutoffvalve and fittings listed below) is
available at exua cost fiom y_nn dealer or fiom Parts and Accessories, 800-626-2002.
>: Cold water supply. The water pressure
must be between
20 and 120 p.s.i, on models
without
a water fiher and between
40 and 120 p.s.i, on models
_dth a water fiher.
i__Power drill.
>: Coppertubing, 1 /4" outer di_uneter to connect the refiigerator
to the water supply. Be sure
both ends of the robing are cut square.
Do not use plastic tubing or plastic fittings because the water supply line is under
pressure at all times. Certain types of plastic tubing may become brittle with age and
crack, resulting in water leakage.
>: Two I/4"outer diameter compression nuts and 2 ferrules (slooves)--to
connect the copper
robing to the shutoffvalve and the refligerator
water valve.
i_:If your existing water line has a flared fitting at the end, you wU1need an adapter(avaiklble at
plumbing supply stores) to connect the water line to the refi'igevamr ORy{)u can {a_tottthe
flared fitting with a tube cuttorand then use a compression
fitting.
>: Shutoff valve to connect
to the cold water line. The shutoffvalve
sh{)uld have a water inlet
with a minimum
inside diameter
of 5/32"
at the point
of connection
to the COLD WATER
LINE. Saddle-type
shutoffvalves
are included
in many water supply
kits. Befi_re purchasing,
make
sure a saddle-t)-pe
x_flve complies
_dth your local plumbing
codes.
15