Vaillant Solar hot water System Manual page 9

Solar system and aurostor unvented solar cylinder
Table of Contents

Advertisement

Technical data of the tube collectors
Appliance designation
Surface area (gross, aperture/net)
Height
Width
Depth
Weight
Collector capacity
Copper pipe connection, flat-face
Insulation: high vacuum
Maximum operating pressure
Pure silver mirror, degree of reflection
Absorber emission
Absorber absorption
Solar sensor sleeve
CE label
Shutdown temperature (according to prEN 12975-2,
c < 1 m/s) in the glass tube
Shutdown temperature (according to prEN 12975-2,
c < 1 m/s) at the collector connection
Efficiency
(according to EN 12975)
0
Efficiency coefficient k
1
Efficiency coefficient k
2
Table 4.1 Technical data tube collector auroTHERM exclusive
[%]
1,0
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0
0
20
40
60
80
1000 W/m
2
Insolation
800 W/m
2
Insolation
300 W/m
2
Insolation
Fig. 4.4 Efficiency of the auroTHERM exclusive according to
DIN 4757/4
Manual - Solar hot water systems
100 120
140 160
180 200 220 240
Temperature difference (collektor/ambient) [K]
auroTHERM exclusive
Description of the components 4
Units
auroTHERM exclusive VTK
275
m
2
0.68 / 0.41
mm
1695
mm
440
mm
100
kg
10.3
l
1.6
Thread
3/4"
-6
bar
10
bar
6
%
94
1
%
5
2
%
95
1.0
mm
6
0036
°C
250
°C
180
%
78
3%
W/(m
2
•K)
1.09
0.2
W/(m
2
•K
2
)
0.01
0.002
40
30
20
10
0
0
50
Fig. 4.5 Pressure loss of the auroTHERM exclusive collector
auroTHERM exclusive VTK
550
1.28 / 0.82
1695
790
100
20
3.56
3/4"
-6
10
6
94
1
5
2
95
1.0
6
0036
250
180
78
3%
1.09
0.2
0.01
0.002
100
150
200
250
Volume flow [l/h]
auroTHERM
exclusive
300
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents