G.shdsl; Lan; Cpe Config; Lan Menu Options - Patton electronics 3231 User Manual

Industrial ethernet extender with lcd interface
Hide thumbs Also See for 3231:
Table of Contents

Advertisement

Model 3231 User Manual

G.SHDSL

Submenu
Line Rate
I-bits
Mode
Annex
Transmit Gain
Eth Link Kill
Noise Margin
Restart DSL

LAN

Submenu
IP Address
Netmask
Default GW

CPE Config

Use this menu on the CO unit to configure the CPE unit.
(None of the items in this menu may be configured if this unit is set as the CPE).
Submenu
CPE Cfg State
CPE Line Rate
CPE IP Address
CPE Netmask
CPE Default GW
Get CPE Config
Set CPE Config
Using the LCD Menu
Table 4. G.SHDSL Menu Options
192 kbps – 4608 kbps
0 – 7
CO or CPE
A or B
-1.6 dB – 1.6 dB
Enabled or Disabled
If enabled, the Ethernet link will go down if the DSL link goes down.
View the noise margin in dB. (This option is not configurable).
Reconfigure DSL and retrain link.
This must be selected after any of the G.SHDSL options are changed (except Eth
Link Kill, which takes effect immediately).
Table 5. LAN Menu Options
Set and modify the LAN IP address
Set and modify the LAN netmask
Set to 000.000.000.000 to remove the default gateway
Table 6. CPE Config Menu Options
Wait until this state reaches Idle before configuring any of the CPE
options. This may take 1-2 minutes after the DSL link comes up. Any changes to
the CPE options that are made before reaching the Idle state will be lost.
192 kbps – 4608 kbps
Set and modify the CPE IP address
Set and modify the CPE netmask
Set to 000.000.000.000 to remove the CPE's default gateway
Request the CPE to report its configuration to this unit.
This is unnecessary because the CO will always reuqest the CPE's configuration
when the link comes up.
Send new configuration to the CPE.
This must be selected after changing any of the parameters in this menu.
2 • Initial Configuration
Options
Options
Options
21