Become familiar with these terms
before operating the unit.
CFM:
Cubic feet per minute.
SOFM:
Standard cubic feet per min-
ute; a unit of measure of air delivery.
PSlG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification:
Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent
safety laboratories and
meet the applicable Underwriters
Laboratories
Standards for Safety.
Cut-In Pressure: While the motor
is off, air tank pressure drops as you
continue to use your accessory. When
the tank pressure drops to a certain
low level the motor will restart auto-
matically. The low pressure at which
the motor automatically
restarts is
called "cut-in" pressure.
Cut-Out
Pressure:
When an air
compressor
is turned on and begins
to run, air pressure in the air tank
begins to build.
It builds to a certain
high pressure before the motor au-
tomatically shuts off, protecting your
air tank from pressure higher than its
capacity.
The high pressure at which
the motor shuts off is called "cut-out"
pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
p':To_o.] $"I,,,_o]_31 $_
This unit is capable of powering the following Accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
Accessories
In Line Filter
Tire Air Chuck
Quick Connector Sets (various
sizes)
Air Pressure Regulators
Oil Fog Lubricators
Air Hose: 1/4", 3/8" or 1/2" I.D. in
various lengths
Refer to the selection chart located on
the unit to select the tools this unit is
capable of powering.
mlll li'i [_'£N II _
This air compressor
pump is capable
of running continuously.
However, to
prolong the life of your air compres-
sor, it is recommended
that a 50%-
75% average duty cycle be main-
tained; that is, the air compressor
pump should not run more than 30-45
minutes in any given hour.
9-ENG
A16751

Advertisement

loading