Download Print this page

Craftsman 919.167280 Owner's Manual page 17

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.167280:

Advertisement

Available languages

Available languages

All maintenance
and repair opera-
tions not listed must be performed
by Trained Service Technician.
Risk of Unsafe
Operation. Unit
cycles automatically
when power is
on. When servicing, you may be
exposed to voltage sources,
compressed
air, or moving parts.
Before servicing
unit unplug or
disconnect
electrical
supply to the
air compressor,
bleed tank of
pressure, and allow the air
compressor
to cool.
To Replace
or Clean
Check
Valve
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off lever to
"OFF" and unplug unit.
3.
Using an adjustable wrench,
loosen outlet tube nut at air tank
and pump. Carefully move outlet
tube away from check valve.
Using a screwdriver, carefully
push the valve disc up and down.
NOTE: The valve disc should
move freely up and down on a
spring which holds the valve disc
in the closed position; if not the
check valve needs to be cleaned
or replaced.
position
nothing
is
visible,
In closed
position
disc is visible.
7.
Clean or replace the check valve.
A solvent, such as paint or varnish
remover can be used to clean the
check valve.
8.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
9.
Replace the pressure release
tube. Tighten nuts.
10. Replace the outlet tube and
tighten nuts.
11. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
4.
Using an adjustable wrench,
loosen pressure relief tube nut
at air tank and pressure switch.
Carefully move pressure relief
tube away from check valve.
5.
Unscrew the check valve (turn
counterclockwise)
using a 7/8"
open end wrench. Note the
orientation for reassembly.
17- ENG
A16751

Advertisement

loading