Initializing A Raid Array - Nvidia ForceWare Software User's Manual

Mediashield
Table of Contents

Advertisement

C
4
HAPTER
Initializing, Rebuilding, and Synchronizing RAID Arrays

Initializing a RAID Array

Initializing a RAID array erases all the data that is stored on that array, and writes all
zeros to the disks. Initialization of newly configured RAID arrays is recommended to
ensure consistency and reliable performance on any supported fault tolerant array such as
RAID 5, RAID 0, and RAID 0+1.
Use this feature only if you are absolutely sure that you want to wipe out all the data on
that array.
Initialization of a fault tolerant array can only be done when the array is being created. To
initialize an array, perform the following steps:
Note: In this example, a mirror array is initialized.
1 From the MediaShield window, right click on any available free disk and select Create
Array as show in
Figure 4.1
The Create Array Wizard opens.
2 Follow the Wizard to create a Mirror array.
See
3 At the Create Array Wizard Welcome screen, click Next.
4 At the RAID Array Selection page, make sure that RAID Mode is set to "Mirroring"
and Stripe Size is set to its default value of 64K, then click Next.
5 At the Free Disk Selection page, select the two drives that you want to Mirror and click
Next.
128
Figure
4.1.
Create an Array to be Initialized
"Creating a Mirrored Array" on page
51.
MediaShield User's Guide – Version 4.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Forceware mediashield 4.0

Table of Contents