Download Print this page

Frigidaire Gallery Series Use & Care Manual page 10

51" stainless steel outdoor grill with electronic ignition
Hide thumbs Also See for Gallery Series:

Advertisement

General
Information
Verify
the type of gas supply
to be used,
either
Natural
Gas (NG) or Liquid
Propane
(L.P).,
and make
sure the
marking
plate
(located
on the back of the unit) agrees
with that of the supply.
Note:
Never
attach
an unregulated
gas line to the appliance.
For Natural
Gas installations,
an installer
must
supply
a gas shutoff
valve
that is easily
accessible
to the grill.
All installer
supplied
parts
must
conform
to local
codes,
or in the absence
of local
codes,
with the National
Electrical
Code,
ANSI/NFPA
70-1990,
and the National
Fuel Gas Code,
ANSI
Z223.1-1998.
All pipe
sealants
must
be an approved
type
and resistant
to the actions
of L.R gases.
Never
use pipe sealant
on flare
fittings.
All gas connections
should
be made
by a competent
technician
and in accordance
with local
codes
and ordinances.
In the absence
of local codes,
the installation
must
comply
with the National
Fuel Gas
Code,
ANSI
Z223.1-1998.
Gas conversions
kits are available
from the I:actory.
When
ordering
gas conversion
kits have the model
number,
and the type of gas (natural
or L.R)
from your grill.
This appliance
and its individual
shut off valve
must be disconnected
from
the gas supply
piping
system
dur-
ing any pressure
testing
of that system
at test pressures
in excess
of 1/2 PSIG
(3.5 kPa.).
This appliance
must
be isolated
I_om the gas supply
piping
system
by closing
its individual
manual
shut-off
valve
during
any pressure
testing
of" the gas supply
piping
system
at test pressures
equal
to or less than
1/2
PSIG
(3.5 kPa.).
The installation
of this appliance
must conform
with local codes,
or in the absence
of local codes,
with
National
Fuel Code,
ANSI
Z223.1 a- 1998.
Installation
in Canada
must
be in accordance
with the Standard
Canl-b149.1
and or .2 (installation
code for
gas burning
appliances
and equipment)
and local
codes.
Natural
Gas
Installation
The gas inlet supply
pressure
should
be between
5" and 14" w.c. A step down regulator
is required
if the line
pressure
is in excess
of 14" w.c.
Check
your local
gas utility
company
or with local codes
for instructions
on installing
gas supply
lines.
Be
sure to check
on type
and size of run, and how deep to bury the line.
If the gas supply
line is too small,
the
grill will not operate
correctly.
Any.joint
sealant
used must
be an approved
type and be resistant
to the actions
of L.R gases.
Place the installer
supplied
shut-off
valve
in an accessible
location
to enable
the gas supply
to be cut off to the
unit.

Advertisement