Your A(3 generator requiressome assembly and is ready
for use after it has been properly serviced with the rec-
ommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at 1-800-
222-3136
Important: Any attempt to run the engine before it has
been serviced with the recommended oil will resultin an
engine failure.
TO REMOVE THE GENERATOR FROM
CARTON
Set the carton on a rigidflat surface with =THIS SIDE
UP" arrows pointing upward.
Carefully open the top flaps of the shippingcarton.
Cut down comers at one end of carton from top to
bottom and lay that side of carton down fiat.
Remove all packing material, carton fillers,etc.
Remove the generator from the shippingcarton.
CARTON CONTENTS
Check all contents. If any parts are missing or damaged,
call the Generator Helpline at 1-800-222-3136.
The main unit
Owner's manual
Engine oil
CORD SETS AND CONNECTOR
PLUGS
120 Volt Duplex Receptacle
Use only high quality, well-insulated, extension cords with
the generator's 120-volt duplex electrical receptacles.
Each receptacle is protected against overload by a push-
to-reset circuitbreaker. Use each receptacle to operate
120 volts, single phase 60 Hz, A C electrical loads requir-
ing up to 2400 watts (2.4 kW) at 20 amps of current.
A
CAUTION!
Although each receptacle is
rated for 120 volts at 20 amps (2400 watts
or 2.4 kW), the generator is rated for a
total of 5000 watts.
Powering loads that
exceed the wattage capacity of the
generator can damage it or cause serious
injuries. The total of loads with 120 volts
powered through these receptacles
should not exceed 20 amps.
Check the ratings of all extension cords before you use
them. Extensioncord sets used should be rated 125 volts
at 20 ac amps or greater for most electrical devices.
Some devices, however, may not require this type of
extension cord. Check the owner's manuals of those
devices for the manufacturer's recommendations.
Keep extension cords as short as possible, preferably
less than 15 feet long to prevent voltage drop and possi-
ble overheating of wires.
120/240 Volt, 20 AMP Receptacle
This receptacle is a NEMA L14-20R and is protected by a
push-to-reset circuit breaker. A NEMA L14-20P mating
connector plug is required to use this receptacle recepta-
cle. Connect a suitable 4-wire cord set to the plug and to
the desired load. The cord set should be rated for 250
volts at 30 amps.
Ire Cord Set
(Neutral)
Y (Hot)
X (Hot)
1201240 VOLTS PLUG
(Green)
A
CAUTION!
Although this receptacle is
rated for 240 volts at 20 amps (4800 watts
or 4.8 kwh, the generator is rated for a
total of 5000 watts (5.0 kW). Powering
loads that exceed the wattage capacity of
the generator can damage it or cause
serious injuries. Loads with 240 volts
powered through this receptacle should
not exceed 20 amps.