How To Use Your Unit; Before First Start Up; Maintenance - Craftsman 919.165580 Owner's Manual

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.165580:
Table of Contents

Advertisement

Available languages

Available languages

Check
Valve:
When the air
compressor
is operating,
the check
valve is
"open",
allowing
compressed
air to enter the air tank.
When the air compressor reaches
"cut-out"
pressure, the check
valve "closes", allowing air pressure
to remain inside the air tank.
Pressure
Release
Valve: The
pressure
release
Pressure
valve,
Release
located on
Valve
the side of
the pressure switch, is designed to
automatically
release compressed
air
from the compressor
head and the
outlet tube when the air compressor
reaches "cut-out"
pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard
escaping from this valve for a few
seconds.
No air should be heard
leaking when the motor is running, or
continuous leaking after unit reaches
"cut-out"
pressure.
Air Intake Filter (not shown): This
filter is designed to clean air coming
into the pump. This filter must always
be clean and ventilation openings
free from obstructions.
See
"Maintenance".
Motor Overload Protector: The
motor has an automatic reset thermal
overload protector. If the motor
overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting.
The
compressor
will automatically
restart
after the motor cools.
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to
"OFF".
Before
First Start Up:
Risk of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not
closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been
replaced.
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph
in the
Installation section of this
manual.)
A00854
14_ ENG