Craftsman 919.165282 Owner's Manual page 17

Permanently lubricated portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench
remove the outlet pressure gauge
and quick connect from the
regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple on the standpipe.
6.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
7.
8.
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten connect with
wrench.
17_ ENG
D27447