Download Print this page

Service And Adjustments - Craftsman 919.165611 Owner's Manual

Permanently lubricated twin v 2-stage stationary air compressor
Hide thumbs Also See for 919.165611:

Advertisement

Available languages

Available languages

d,(ollJ :] l :_'_"[oIo]l | I _B
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
PROBLEM
Excessive tank
pressure - safet
valve pops off.
Air leaks at
fittings.
Air leaks at or
inside check
valve
CAUSE
Pressure switch does not
shut off motor when
compressor
reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
CORRECTION
Move On/Auto/Off
lever to
the "OFF" position,
if the
outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. Do Not
Overfi£1hten.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor is
shut off. Replace check
valve. Refer the '*To Replace
or Clean Check Valve" in the
"Service and Adjustment"
section.
Air leaks at
Defective pressure switch
Contact a Trained Service
pressure switch
release valve.
Technician.
release valve.
Defective air tank.
Air leaks in air
tank or at air
tank welds.
Air leaks
Leaking seal.
between head
and valve plate.
D29312
20- ENG
Air tank must be replaced.
Do not repair the leak.
Do not drill into, weld or
otherwise
modify air tank
or it will weaken. The tank
can rupture
or explode.
Contact a Trained Service
Technician.

Advertisement

loading