Preparation For Use; Pre-Start Checklist; Initial Set-Up; Lifting - DeWalt D55168 Instruction Manual

Oil free portable air compressor
Hide thumbs Also See for D55168:
Table of Contents

Advertisement

Available languages

Available languages

LIFTING
Always use two people when lifting and lift from
the recommended
lift points (O). DO NOT lift
by wheels or shroud.
Moving
_CAUTION:
The wheels
and
handle do
not provide adequate clearance, stabitity, or
support for pulling the unit up and down stairs
or steps. The unit must be lifted or pushed up
a ramp.
1. Grasp handle of compressor and tilt compressor back to rest on
wheels.
_2_ W ARNING: Risk of Unsafe Operation. Ensure proper footing and
use caution when roiling compressor so that unit does net tip or
cause loss of balance.
2 When location is reached slowly lower compressor to ground.
Always store compressor
in a vertical position resting on the
rubber bumpers and wheels.
PREPARATION
FOR
USE
Pre=Start
Checklist
(Fig.
I)
1 Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle See
Voltage and Circuit Protection
under Installation.
3 Ensure air tank is drained,
see Draining
Air Tank under
Maintenance.
4 Ensure the drain valve (H) is closed.
5 Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Pull the knob (D) out and turn clockwise to increase pressure
and counterclockwise to decrease pressure. When the desired
pressure is reached push knob in to lock in place.
7. Attach hose and accessories
CAUTION: Risk of unsafe operation. Compressed air from the unit
may contain water condensation and oil mist. Do not spray unfiltered
air at an item that could be damaged by moisture. Some air tools and
accessories may require filtered ai_ Read the instructions for the air
tools and accessories.
_WARNING:
Risk of Bursting. Too much air pressure causes a
hazardous
risk of bursting
Check the manufacturer's
maximum
pressure rating for air tools and accessories.
The regulator outlet
pressure must never exceed the maximum pressure rating.
Initial
Set.up (Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction
manual
for safety,
operation
and maintenance
instructions.
BREAK-IN PROCEDURE
_WARNING:
Risk of property damage. Serious damage may result ff
the following break-in instructions are not closely fellowed.
This procedure is required before the air compressor
is put into
service for the first time and when the check valve or a compressor
pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pulI coupler
back until it clicks to prevent air from escaping through the quick
connect.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection
under Installation.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents