Craftsman 226.165291 Operator's Manual

Permanently lubricated tank mounted air compressor

Advertisement

Quick Links

Operator's
Manual
[RRFTSMRN°
Permanently Lubricated
Tank Mounted
AIR COMPRESSOR
Model No.
226.165291
CAUTION:
Read and follow
all Safety Rules and Operating
Instructions before First Use
of this Product.
• Safety Rules
• Operation
• Maintenance
• Parts List
Sears, Roebuck and Co., Hoffman Estates, IL 60179LU _
17939.02 Draft (06/19/02)

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 226.165291

  • Page 1 Operator's Manual [RRFTSMRN° Permanently Lubricated Tank Mounted AIR COMPRESSOR Model No. 226.165291 CAUTION: Read and follow • Safety Rules all Safety Rules and Operating • Operation Instructions before First Use • Maintenance of this Product. • Parts List Sears, Roebuck and Co., Hoffman Estates, IL 60179LU _ 17939.02 Draft (06/19/02)
  • Page 2 If this Craftsman air compressor falls due to a defect in materi- al or workmanship within one full year from the date of pur- •...
  • Page 3: Location Of The Air Compressor

    Cut-Out Pressure: When a naircompressor isturned o n fit in outlet, have proper outlet installed by a qualified electrician. begins to run, air pressure in the air tank begins to build, it builds to a certain high pressure before the motor automati- •...
  • Page 4: Voltage And Circuit Protection

    Pressure Gauge DESCRIPTION The Craftsman permanently lubricated air compressor con- sists of a one cylinder, single-stage air compressor pump and air tank. This air compressor requires no oil.Your air compres- sor can be used for operating paint spray guns, air tools, blow...
  • Page 5: Before First Use

    • Check Valve: When the air compressor is operating, the • Open the drain valve fully (counter-clockwise) to permit air check valve is "open", allowing compressed air to enter the to escape and prevent air pressure build up in the air tank air tank.
  • Page 6 AFTER EACH USE: • Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper, closed • Set the "Auto/Off" lever to "OFF". position. The check valve may be cleaned with a solvent, •...
  • Page 7: Air Filter - Inspection And Replacement

    MOTOR NOTE: Arrow on (bottom of regulator) indicates flow of air. Make sure it is pointing in the direction of air flow. The motor has an manual reset thermal overload protector.If the motor overheats for any reason, the overload protector will shut off the motor.
  • Page 8 CORRECTIVE ACTION SYMPTOM POSSIBLE CAUSE(S) Excessive tank pressure 1. Pressure switch does not shut off 1. Move the pressure switch lever to the "OFF' position. - safety valve pops off motor when compressor reaches If the compressor doesn't shut oft, disconnect from cut-out pressure the electrical outlet and return to a Sears Service Center to replace the pressure switch...
  • Page 9 SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSE(S) Motor will not run or 1. Present tank pressure exceeds pres- 1. Motor will start automatically when tank pressure restart sure switch "cut-in" pressure drops below "cut-in" pressure of pressure switch 2. Fuse blown, circuit breaker tripped 2a.
  • Page 10 Model 226.165291 Figure 13 - Replacement Parts Illustration for Air Compressor...
  • Page 11 PART NO. DESCRIPTION QTY. 17699.00 Cylinder Head 17900.00 6-1.0 x 80mm Socket Head Bolt STD852006 6mm Lock Washer* 17901.00 Exhaust Elbow 17902.00 Relief Valve 17903.00 Gasket 17904.00 Valve Plate 17905.00 Cylinder Head O-ring 17906.00 Cylinder 17907.00 Piston-Rod Assembly STD315225 6202zz Ball Bearing* 00533.00 3AM1-15 Retaining Ring 17906.00...
  • Page 12 In U.S.A. or Canada for in-home major brand repair service: Call 24 hours a day, 7 days a week 1-800-4-MY-HOME '_ (1-800-469-4663) Para pedir servicio de reparaci6n a domicilio - 1-800-676-5811 Au Canada pour tout le service - 1-877-LE-FOYER °" (1-877-533-6937) For the repair or replacement parts you need: Call 6 a.m.