bottom of the label liner or tag. The eye-mark must not reflect more than 12% of the light. Since the same
receiving sensor is used for all three types of sensing, it must be calibrated with the media that will be used. The
ribbon must be installed while the calibration is being performed.
Print
Head
When calibrating the printer sensors, the gap or eye-mark sensor type must be selected first using the <ESC>CI
command and then the Direct Thermal or Thermal Transfer print mode must be specified with an <ESC>CP
command. These two commands are followed by an <ESC>CA Calibrate command to instruct the printer to
perform the calibration procedure. The resulting calibration values are stored in the printer and used until the
unit is recalibrated. A separated value is stored for direct thermal or thermal transfer modes because the settings
will differ significantly because of the inclusion of the ribbon for thermal transfer. For example, the following
command string will calibrate the printer in the thermal transfer mode for gap sensing:
<ESC>A<ESC>CP1<ESC>CI2<ESC>CA<ESC>Z

COMMAND CODE PAGE REFERENCE

This section contains all the printer Command Codes. The commands must be sent to the printer in an organized
fashion in order for the label(s) to print.
The purpose of this section is to:
Max Left Margin
4mm
Sensing Width: 8mm
Adjustable Position Sensor
Min Label Width
13mm
10
Gap, Notch or Bar Height
2mm~25mm
Min Label Pitch
10mm