Electrical Preparation - HP Surestore HVD10 - Disk System Service Manual

Hp surestore e disk system hvd10 user and service guide - a5616-90901
Table of Contents

Advertisement

Electrical Preparation

No. of Disk Systems
on Circuit*
1
2
3
4
Incoming Voltage
AC RMS
100 – 120 volts
200 – 240 volts
Caution
Adding disk systems with two power supplies to 120V circuits rapidly increases
amp requirements. Always make sure that the total current drawn does not
exceed circuit capacity.
42
Inrush Current and Duration
10 amps declining over 10 to 12 cycles
20 amps declining over 10 to 12 cycles
30 amps declining over 10 to 12 cycles
40 amps declining over 10 to 12 cycles
Maximum RMS Current Drawn by One
Disk System
6.5 amps
3.2 amps