OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = (capacity (MB) specified
by user) × 16/15 × n
Example
For an OPEN-V CVS LUSE volume with capacity = 49 MB and n = 4:
# of cylinders =
49 × 16/15
× 4 =
52.26
× 4 = 53 × 4 = 212
Note 7:
The capacity of an OPEN-3/8/9/E CVS volume is specified in MB, not number of cylinders. The
capacity of an OPEN-V CVS volume can be specified in MB or number of cylinders. You set the
volume size using XP Remote Web Console or XP Command View Advanced Edition Software.