Product Dimensions - Whirlpool 3397612 Installation Instructions Manual

Thin twin washer/dryer - 240 volt
Table of Contents

Advertisement

Recessed and closet
installation
instructions
r*
--I -
*
f ront view
side view
Mlnlmum lnstallatlon spacing
Fire Hazard
It is recommended that the
washer/dryer be exhausted to the
outside.
If washer/dryer is installed in a closet,
the dryer MUST be exhausted outside.
Failure to do so may result in a fire.
TO PREVENT LARGE AMOUNTS OF LINT
AND MOISTURE FROM ACCUMULATING,
TO MAINTAIN DRYING EFFICIENCY AND
TO PREVENT EXPOSURE TO POSSIBLE
HEALTH HAZARDS, THIS WASHER/DRYER
SHOULD BE EXHAUSTED OUTDOORS.
This washer/dryer
may be installed in a
recessed area or closet.
The installation spacing is in inches and
is minimum allowable.
Additional
spacing should be considered
for ease
of installation, servicing and compliance
with local codes and ordinances.
If closet door is installed, the minimum
unobstructed
air openings in top and
bottom are required. Louvered doors
with equivalent
air openings are
acceptable.
I
C
exhausted.
Other installations must use the minimum
dimensions indicated.
Recessed and closet
:nstalIation
nstructfons
Recessed installation
3" j
Note: If recessed installation is exhausted, all
spacing can be 0 in.
Additional clearance for wall, door and floor
molding may be required.
Closet installation
closet door
I
front view
Unobstructed air openings are minimum for closet
door. louvered door with equivalent air openings
is acceptable.
24
1 Additional
i-
sq. In.
i-l
ic
-4 k
'"
side view
Product dimensions
(Shown wlth legs extended
1 Inch from
bottom ot washer/dryer.)
24"
L-1
12'
.
c
rear view
+27-1/C'+
side view
Closet installation must be exhausted outdoors.
Recessed, non-exhausted
installation must use
only the rear exhaust position and Exhaust
Deflector Kit No. 4500 Is required.
Panel G

Advertisement

Table of Contents
loading