Other Information Indicating; 12 Groups Of Date Constitutes Of A Frame - Epson Weighing Indicator XK3190-A1+P User Manual

Epson weighing indicator user's guide
Table of Contents

Advertisement

3 Err 21
Calibrating data have been lost in RAM and EPROM, Operator must
put
in the calibration plug, then reenter the original calibration data, turn
on the indicator again or re-calibrate it.
4 Err 22
EPROM has been damaged.
5 Err 23
RAM has been damaged.

6.6 Other information indicating

1. Err 24
In normal operation, you must pull off the calibration jumper.The
indicator is under normal operation, and the calibration jumper shouldn't be put in. If
calibration is needed, the calibration jumper should be put in at set-up. You should pull
out the calibration jump when turning off the indicator. If the indicator finds that the
calibration jump was inserted when turning on, it will display Err 24 for 6 seconds
to
prompt the operator.
2 Err 25 Illegal software, or E2PROM was damaged
.

12 groups of date constitutes of a frame

Date No. in a frame
1
2
3
4
5
6
7
8
9
10
11
12
X K 3 1 9 0 - A 1
explanation
02 (X ON) ,
+ or - ,
Weight date
Weight date
Weight date
Weight date
Weight date
Weight date
Decimal position, from right to left (0 – 4)
Checking XRL, higher 4 bits
Checking XRL, lower 4 bits
03 (X OFF)
+P
start
END

Hide quick links:

Advertisement

Table of Contents
loading