Programming Non-Plu Code Format (#2025) - Sharp ER-A440S Instruction Manual

Hide thumbs Also See for ER-A440S:
Table of Contents

Advertisement

Programming Non-PLU code format
The register allows you to specify the Non-PLU code format (flag code: 2, 02, 20 -29).
The format data is as follows:
Flag
(02 or 20-29)
Procedure
.
2025
1
*
Flag code: 2, 02, 20 - 29
2
*
Item:
A
Length of field 1 (number of digits)
B
Length of field 2 (number of digits)
C
Meaning of field 1*
D
Meaning of field 2*
E
Price check digit used
F
TAB or decimal point of field 2 (0, 1, 2, 3)
3
*
: When you select Dept. code, the sales are counted up as the sales of the department (associated
department assignment is ignored.), and when you select PLU code, the sales are counted up as the sales of
the PLU code, while they are counted up as EAN sales for sales reports.
4
*
: When you select quantity, the sales amount is calculated as follows: quantity x unit price programmed in
#1010.
Example
2 0
Flag
code
Free format
Field 1
Free format area
1
*
Flag code
(max. 2 digits)
3
4
P
D
PLU code
Price check digit
Key operation
. ≈
2025
20
:
540012
;
PGM 2
2025
C
2
D
Flag
Price check digit
Field 2
To delete
2
*
A B CD E F
Selection:
Free code
Dept. code
PLU code
Quantity
Price
Yes
No
C
D
Price
(TAB2)
Flag code
C
D
Free format
:
Entry:
0 - 9
0 - 9
2
1
0
2
0
1
0
0 - 3
Print
;
ABCDEF
59

Hide quick links: