Download Print this page

Zenith L26W58HA Installation And Operating Manual page 49

Advertisement

(Continued from previous page)
The value range is 0 to 63, with 63 as the default, which gives the
user the full range of volume corrtro[, if item 008 MIN VOLUMEis
aLso set at O. Change values with ADJ Left/Right arrow keys. It may
be best to set the same value on every L26WS8HA.
*Note: The maximum
volume level cannot have a value setting
lower
than the MIN VOLUMElevel (desc6bed previously).
010 - MUTE DISABLE
Enables or disables sound mute function.
If set to 1, sound cannot
be muted, mute is disabled. If set to O, sound can he muted.
011 - KEY DEFEAT(Keyboard Defeat)
If set to 1, key defeat prevents the end user from accessing the on-
screen menus with the display front panel--MENU, SELECT,and Left /
Right arrow keys and TV!AV do not function.
If set to O, those keys
do function.
*Note: The menus can always be accessed by pressing MENU on the
remote.
012 - IR BANKS EN. (IR Banks Enabte)
For direct access to a particular Channel Bank. When enabled,
installer can access a chamlel bank by inputtin 9 the IR code fol the
bank.
013 - SCAN MODE
ALLowsvariation in setting the On/OFFwith Channel UP/DOWN.
You may opt for TV channels only; TV channeLs + OFF/ON;TV
channeLs + FM radio; TV channels + FM radio + Off/On with these set-
tings for Scan Mode:
SCAN MODE
0
Characteristics
Channel up/down keys change channels only.
Channel down below the lowest channel
(or channel up higher than the highest) and TV
turns off.
014 - STRT CH IN SM (Start Channel in Scan Mode)
When set to 1, instaLLs TV On/OFF event below the start channetat TV
turn on.
015 - SLEEP TIMER
Ifsetto I,theSLEEP TIMER featuremay be used.Ifsetto O, the
Sleep limerisnot avai[abte.
016 - EN TIMER (EnableOn/OFF Timers)
Ifsetto I,Timerfunction isavailable t o user. Set to 0 to disable
On/OffTimer functions. (CLock must be setin orderto use Timers.)
017 - ALARM
Gives the ins{aLter the option of making the ALarm function
avaiLabLe
to the end user. If set to 1, Alarm function is avaiLab{e to end user.
Set to 0 to disable the ALarm function.
*Note: Clock must be set before the Alarm function
will work.
Installer
should leave item 20 FEATURELEVEL set to 1 (default).
020 - FEATURELEVEL
_k
efault set to ZEN 1 for Zenith IR remote control opera-
tion. Set O, P LBL for Zenith Private Label IR remote con-
trot operation.
Warning: Do not set to "0" or remote will
not control IV.
021 - V-CHIP (Parental Control)
Set to 1 to activate V-Chip (Parental Control); have it avaiLabLe to
end user to fi[ter and control or otherwise restrict programming
content that can appear. Set to 0 to turn V-Chip feature OFF,not
availab[e to user; no programming restrictions can be set.
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours fiom 0 to 99 for the maximum V-Chip (Parental Control)
block hours. Default setting is for 12 b[ocking hours.
023 - CAPTION LOCK
Set to 1 to restore previous caption On/OFF state after turn OFF.If set
to O, captions are always Off at turn On.
025 - FUNCTION PRE. (FunctionPreview)
Set to 0 to suppress CHANNEL PREVIEW from the FUNCTION menu
with some Pay-Per-View s ystems.
027 - HOSPITAL MODE
The defauR is2 (whichfavorsmost hospitals). With thissetting two
thingsare affected: C hannelBanks I, 2,and 3 areaccessible, while
Bank 4 is inactive.
028 - CH. OVERIDE (Channel Override)
Ifsetto I,the usercan select channelswith either Channel
up/down or by direct keypad entry. Ifsetto O, onlythose channeLs
thatareenteredforscanningcan be selected.
029 - OLD OCV (On Command
Video
TM)
Set to 1 for operation with systems from On Command Corporation.
030 - ACK MASK
M.P.I. Communication Parameter. Leave at default setting unless
changed by Pay-Per-View provider. When set to 1, changes M.P.I. for
some OCV boxes.
031 - POLL RATE
M.P.I. Communication Parameter. Selects Poll Rate for M.P.I. Leave at
default setting
unless changed by Pay-Per-View provider. Step size of
16 ms.
032 - TIMING PULSE
M.P.I. Communication Parameter. Leave at default setting unless
changed by Pay-Per-View provider. Sets baud rate. Step size of 4.3
uS.
034 - CAMPORT EN. (Camera Port Enable)
Set to 1 to enable Video 2 input on display panel. If set to O, Video
2 input on display
panel is not functional
PAG
E 49

Advertisement

loading