HP StorageWorks P9000 User Manual page 53

Business copy user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 14 RAID Manager error codes (SSB1 code: b9a0/b9a1/b9a2/b9a5/b9a6/b9ae/b9af)
(continued)
SSB2 code
Description
2351
Because the volume specified as the P-VOL and the volume specified as the S-VOL was the same one,
the pair operation was rejected.
2352
Because the specified P-VOL and S-VOL was online to the host, the quick restore operation or the
reverse copy operation was rejected.
2353
Because the specified P-VOL and S-VOL was being split by using quick split, the pair deletion was
rejected.
2354
Because the P-VOL and S-VOL was being split by using steady split, the pairresync operation was
rejected.
2357
The pair creation was rejected because the volume specified as the S-VOL was the P-VOL of the splitting
pair, or the P-VOL of the pair where the reverse copy operation or quick restore operation is being
performed.
2358
Because the volume specified as the S-VOL was the P-VOL of the splitting pair, the pairresync operation
was rejected.
235b
The volume specified as a P-VOL was a P-VOL of a Continuous Access Synchronous pair. Because
the status of the Continuous Access Synchronous pair was not PSUE, the reverse copy or the quick
restore operation was rejected.
235c
The volume specified as a P-VOL was an S-VOL of a Continuous Access Synchronous pair. Because
the status of the Continuous Access Synchronous pair was not PSUE, the reverse copy or the quick
restore operation was rejected.
235d
The volume specified as an S-VOL was a P-VOL of a Continuous Access Synchronous pair. Because
the status of the Continuous Access Synchronous pair was not PSUE, the reverse copy or the quick
restore operation was rejected.
236C
Because the volume specified as the P-VOL has S-VOL Disable attribute assigned by the Data Retention,
the quick restore operation or the reverse copy operation was rejected.
236D
Because the volume specified as the S-VOL has S-VOL Disable attribute assigned by the Data Retention,
the pair operation was rejected.
2370
Because the volume specified as the P-VOL was not mounted, the pair operation was rejected.
2371
Because the volume specified as the P-VOL was blocked or a system disk, the pair operation was
rejected.
2372
Because the volume specified as the P-VOL was being formatted, the pair operation was rejected.
2373
Because the volume specified as the P-VOL was a command device, the pair operation was rejected.
2380
The operation was rejected for one of the following reasons:
Because the volume specified as the S-VOL was not mounted, the pair operation was rejected.
Because the MU number was 3 or more, the pair operation was rejected.
2381
Because the volume specified as the S-VOL was blocked or a system disk, the pair operation was
rejected.
2382
Because the volume specified as the S-VOL was being formatted, the pair operation was rejected.
2383
Because the volume specified as the S-VOL was a command device, the pair operation was rejected.
2385
Because the volume specified as the P-VOL was a reserved volume for Auto LUN, the pair operation
was rejected.
2386
Because the volume specified as the S-VOL was a reserved volume for Auto LUN, the pair operation
was rejected.
2387
Because the volume specified as the P-VOL was the volume for Auto LUN, the pair creation was
rejected.
Troubleshooting with RAID Manager
53

Advertisement

Table of Contents
loading

Table of Contents