DFX-8500
2.1.3 Platen Gap Adjustment Mechanism
Figure 2-6 shows the platen gap adjustment
mechanism.
The front and rearcaniage
guide shafts supporting
the carriage have a vertical
section.
The rotation
of the PG motor is transmitted
to the rear carriage guide
shaft through
the gears.
Counterclockwise
rotation
of the motor
expands
the platen gap and clockwise
rotation reduces it.
The encoder plate with equally
pitched slits is attached
coaxially
to the motor axis. When the motor rotates,
the PC sensor detects
it and outputs
the pulses.
Each pulse corresponds
to detection
of a 0.0025 mm
resolution (horizontal distance).
The system range is 0.35 to 0.84 mm.