Power Supply
Option slot power limits
Maximum Current
For each slot
For all four slots
Environmental Requirements
Condition
Temperature
Humidity
(non-
condensing)
Altitude
Maximum
wet bulb
Acoustical
noise
A-4 Specifications
+5 Volts
7 Amps
16 Amps
Operating range Non-operating
41° t0 90° F
(5° to 32° C)
20% to 90%
-330 to 9,900 ft
(-100 to 3,000 m)
68° F
(20° C)
37.5 dB(A)
-5 Volts and -12 Volts
+12 volts
0.3 Amps
1.5 Amps
0.3 Amps
3 Amps
range
- 4 ° t o 1 4 0 ° F
(-20° to 60° C)
10% to 90%
-330 to 39,600 ft
(-100 to 12,000 m)
104°F
(40° C)
N/A
Storage range
-4° to 140° F
(-20° to 60° C)
10% to 90%
-330 to 39,600 ft
(-100 to 12,000 m)
134° F
(57° C)
N/A