6. Turn the knob on the gas control clockwise (
the black line, depress slightly, and turn to "OFF" posi-
tion. See Figure 4.
Gas control is shown ON.
Turn Clockwise and press
down to turn gas off.
You are
here
FIGURE 4: Turning Gas Control OFF
7. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow "B" in the "Before Startup"
instructions (Page 4). If you don't smell gas, go to the
next step.
8. Turn the knob on the gas control counter-clockwise
(
) to the "ON" position. See Figure 5.
Gas control is shown OFF.
Turn Counter-clockwise
and release to turn gas on.
You are
here
2672 1096
FIGURE 5: Turning Gas Control ON
9. Replace jacket cover(s). All jacket covers must be in
place when operating the appliance.
10. Set 3-way valves on inlet and outlet to pool or spa, as
) to
11. Turn on all electric power to the appliance.
12. Press either the POOL ON or SPA ON button switches
Indexing Point
13. Set the thermostat to desired setting (NOTICE: Set
14. The blower should come on immediately, and after
15. The burner should fire until the pool/spa temperature
Gas is now OFF
You are here
2671 1096
16. If the appliance will not operate, follow the instruc-

TO TURN OFF GAS TO THE APPLIANCE

1. Depress OFF button on operating control.
Indexing Point
2. Turn off all electric power to the unit.
3. Remove jacket cover(s). See Figure 3.
4. Turn the knob on the gas control clockwise (
5. Replace jacket cover(s).

OPERATING CONTROL

Gas is now ON.
You are here
FIGURE 6: Operating Control. See Page 36 for External
Control Interface.
6
appropriate.
on the operating control.
point must be above actual water temperature or burn-
er will not fire). See OPERATING CONTROL below.
about 20 seconds, the burner should fire. When oper-
ating for the first time, the burner may not fire on the
first try because of air in the gas line. If it does not fire
at first, push the OFF switch, wait five minutes, and
again push the POOL or SPA ON switch. The burner
should fire after about 20 seconds. You may have to
repeat this until all of the air has cleared the gas line.
reaches the desired temperature set on the thermostat.
The blower will continue to run for about 45 seconds
after the burner shuts off. If any of the safety interlocks
should open during burner operation, the burner shuts
off immediately, but the blower continues to run for
about 45 seconds.
Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the
appliance.
tions "TO TURN OFF GAS TO THE APPLIANCE", and
call your service technician or gas supplier.
HEATER PARTS MAY BE HOT.
the black line, depress slightly, and turn to "OFF" posi-
tion. See Figure 4.
LOW SPEED
BOOSTER PUMP
HIGH SPEED
System Operation
FILTER
Indicator Lights
PUMP
) to
Digital Temperature
Display
TemperatureUp/Down
AUX
AUX
2
1
Dual Temperature
Controls