Maintenance - Craftsman 919.167220 Owner's Manual

Permanently lubricated single stage portable
Hide thumbs Also See for 919.167220:
Table of Contents

Advertisement

Available languages

Available languages

Customer
Responsibilities
Before Daily or
after
Every Every
each
each
40
100
Yearly
use
use
hours hours
Check Safety Valve
O
Drain Tank
Air Filter
O(1)
Air compressor
pump intake
and exhaust valves
1- more frequent in dusty or humid conditions
Unit cycles
--
automatically
when
power is on. When performing
maintenance,
you may be exposed
to voltage sources,
compressed
air, or moving parts. Personal
injuries can occur. Before
performing
any maintenance
or
repair, disconnect
power source
from the compressor
and bleed off
all air pressure.
To ensure efficient operation and
longer life of the air compressor
outfit, a routine maintenance
schedule should be prepared and
followed. The following routine
maintenance schedule is geared to
an outfit in a normal working
environment
operating on a daily
basis. If necessary, the schedule
should be modified to suit the
conditions
under which your
compressor
is used. The
modifications
will depend upon the
hours of operation and the working
environment.
Compressor
outfits in
an extremely dirty and/or hostile
environment will require a greater
frequency of all maintenance checks.
NOTE: See "Operation"
section for
the location of controls.
To Check
Safety
Valve
If the safety valve
does not work
properly,
over-pressurization
may
occur, causing
air tank rupture
or
an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain
Tank
1.
Set the On/Auto/Off
lever to
"OFF".
2.
Pull the regulator knob out and
turn clockwise to set the outlet
pressure to zero.
3.
Remove the air tool or
accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
Water will
--
condense
in the air
tank. if not drained,
water will
corrode
and weaken
the air tank.
D26543
16- ENG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents