Summary of Contents for Gardena RP 240

  • Page 1 ® GARDENA Gebrauchsanweisung Zimmerbrunnenpumpe Operating Instructions Indoor Fountain Pump Mode d’emploi Pompe pour fontaine d’intérieur Art. 7834 Art. 7835 Gebruiksaanwijzing Binnenshuis-fonteinpomp RP 240 / RP 300 / RP 420 Bruksanvisning Pump för inomhusfontän Istruzioni per l’uso Pompa per fontana da interni...
  • Page 2: Table Of Contents

    Indoor Indoor Fountain Pump. v Please keep these operating instructions in a safe place. Contents : 1. Where to Use Your GARDENA Indoor Fountain Pump ..2. Safety instructions ..........
  • Page 3: Where To Use Your Gardena Indoor Fountain Pump

    1. Where to Use Your GARDENA Indoor Fountain Pump Correct use : GARDENA Indoor Fountain Pumps have been designed for pri- vate use around your house. They are not designed for operating watering tools and systems. Pumps RP 240 / RP 300 / RP 600 must only be used indoors.
  • Page 4 Mains power cables must not have a smaller replaced. If the cable is damaged the pump cross-section than a PVC cable of the must be disposed of. designation H03 VV (RP 420 of the Do not use the power cable to carry the pump designation H05 RNF).
  • Page 5: Initial Operation

    The temperature of the liquid used must not Please observe the local noise prevention be below 4 °C or above 35 °C. regulations. Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump. 3.
  • Page 6 Commissioning the pump if If the pump is installed out of water, the filter housing must it is installed out of water : be taken off. 1. Pull off the filter housing 2. Turn the pump inlet anticlockwise and pull it vertically off the motor housing (bayonet socket).
  • Page 7: Storage

    4. Storage Storage : The fountain pump must be stored out of the reach of children. 1. Before the frosty season begins, ensure the fountain pump has been cleaned and is stored indoors. 2. To avoid difficulties when starting up in the spring, we recom- mend storing the pump in a frost-free location in a container filled with water.
  • Page 8: Cleaning

    5. Cleaning DANGER ! Electric Shock ! Risk of injury due to electric shock. V Before cleaning the pump, unplug it from the mains. Do not use any hard tools or aggressive cleaners on the pump. Cleaning the 1. Remove foam filter by pulling down and clean it.
  • Page 9 Cleaning the RP 600 : 1. Pull off the fountain socket and nozzle tube 2. Unscrew the fountain insert and clean it. 3. Remove the filter housing from the motor housing , and clean it. 4. Turn the pump inlet anticlockwise and pull it vertically off the motor housing (bayonet socket).
  • Page 10: Troubleshooting

    Foam filter / filter housing v Clean the foam filter / filter reduced water flow dirty. housing. CAUTION ! Work on the electrical parts must only be carried out by GARDENA Service Centres. If other faults occur, please contact GARDENA Service.
  • Page 11: Accessories

    Illuminates fountains from below or Art. 7952 UL 20 / UL 20 S Set above the surface of the water Art. 7958 GARDENA radio control set Start water features and lighting from Art. 7874 the terrace or your living room. 8. Technical data...
  • Page 12: Service / Warranty

    Service or return the defective unit together with a short description of the problem – in case of guarantee, with a copy of the receipt – postage paid to one of the GARDENA Service Centres listed on the back of this leaflet.
  • Page 13 0,20 0,15 0,10 0,05 10 l / min...
  • Page 14 We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist.
  • Page 15 GARDENA dele eller dele godkendt af os, eller hvis reparationerne ikke er udført af GARDENA-service eller en autoriseret fagmand. Det samme gælder for ekstra udstyr og tilbehør.
  • Page 16 Bezeichnung des Gerätes : Zimmerbrunnenpumpe Typ : Art.-Nr.: Description of the units : Indoor Fountain Pump Type : Art. No.: RP 240 7834 Désignation du matériel : Pompe pour fontaine d’intérieur Type : Référence : RP 300 7835 Omschrijving van de apparaten : Binnenshuis-fonteinpomp Tip : Art.
  • Page 17 Sofia 1404 Industrial Area Koropi Czech Republic Calle Colonia Japonesa s / n Phone: (+ 359) 2 958 18 21 194 00 Athens Greece GARDENA spol. s r.o. (1625) Loma Verde office @ denex-bg.com V.A.T. EL093474846 Шнpskб 20 a, и.p. 1153...
  • Page 18 Phone: (+ 65) 6253 2277 hyray @ singnet.com.sg Japan Switzerland / Schweiz Poland KAKUICHI Co. Ltd. GARDENA (Schweiz) AG GARDENA Polska Sp. z o.o. Slovak Republic Sumitomo Realty & Bitziberg 1 Szymanów 9 d GARDENA Slovensko, s.r.o. Development Kojimachi 8184 Bachenbülach 05 - 532 Baniocha Panónska cesta 17...