Fujitsu MAY2036RC Product/Maintenance Manual page 66

Hide thumbs Also See for MAY2036RC:
Table of Contents

Advertisement

Diagnostics and Maintenance
Brief test contents of self-diagnostics are as follows.
a. Hardware function test
This test checks the basic operation of the controller section, and contains following test.
RAM (microcode is stored)
Peripheral circuits of microprocessor (MPU)
Memory (RAM)
Data buffer
b. Seek test
This test checks the positioning operation of the disk drive using several seek modes (2 points
seek, 1 position sequential seek, etc.). The positioning operation is regarded as success when the
seek operation to the target cylinder is completed.
c. Write/read test
This test checks the write/read function by using the Internal test space of the disk drive.
(1)
Initial self-diagnostics
When the HDDs are turned on, they run the initial self-diagnostics. The initial self-diagnostics test
the basic operations of hardware functions.
If the initial self-diagnostics detect an error, the LED on the drive blinks. The HDDs in this state
post the CHECK CONDITION status to all I/O operation requests except the REQUEST SENSE
command. The initiator can collect sense data when the CHECK CONDITION status is posted.
Sense data contains detailed information on the error detected by the initial self-diagnostics.
When sense data has been collected after the CHECK CONDITION status has been posted, the
CHECK CONDITION status continues and the LED keeps blinking. This status can be cleared only
when the HDDs are turned off and turned on again. When the status is cleared, the HDDs run the
initial self-diagnostics again.
The HDDs do not reply to requests from the host system for a maximum of 2 seconds after the start
of the initial self-diagnostics. Thereafter, the HDDs can accept I/O operation requests normally, but
any received command, except commands that are executable even in the not ready state, is
terminated with the CHECK CONDITION status until the spindle motor reaches the normal
rotational speed and the HDDs become ready. The commands that are executable even in the not
ready state are executed in parallel with the initial self-diagnostics, or they are queued by the
command queuing feature and executed when the initial self-diagnostics is completed.
If the initial self-diagnostics detect an error, the CHECK CONDITION status is posted for all of the
commands received and queued during the initial self-diagnostics.
6-2