PROBLEM
Pressure readinc
on the regulated
pressure gauge
drops when an
accessory is
used.
Knocking Noise.
Compressor
is
not supplying
enough air
to operate
accessories.
CAUSE
It is normal for "some"
pressure drop to occur.
Possible defect in safety
valve.
Defective check valve.
Prolonged excessive use of
air.
Compressor
is not large
enough for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Restricted air intake filter.
CORRECTION
If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions
in the
"Description
of Operation"
paragraph in the "Operation
Section.
NOTE: Adjust the regulated
pressure under flow
conditions
(while accessory is
bein
used.
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.
Remove and clean, or
replace.
Decrease amount of air
usage.
Check the accessory air
requirement.
If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Remove and clean, or
replace.
Tighten fittings.
Clean or replace air intake
filter. Do not operate the
air compressor with the
filter removed. Refer to the
"Air Filter" paragraph in the
Maintenance"
section.
Damaged regulator.
Replace.